K1: Mode group, channel, program operation, reset response
9.9 Program operation mode
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
561
Dependent on machine data MD10711
$MN_NC_LANGUAGE_CONFIGURATION
= (set value) results in the following interpretations of the option and
function relative to their programmability 2xx:
Definition for option/function:
0 corresponds to option not activated or function deactivated
1 corresponds to option/activated or function activated
For more detailed information on the value ranges of 2xx programmable functions, see
References:
/PGA/ Job Planning Programming Manual; Other Functions, "STRINGIS"
9.9.2
Selection and start of part program or part-program block
Reset status
Channel status
A part program can be selected only if the relevant channel is in the Reset state.
Start command, channel status
There are two possible START commands for initiating processing of a part program or part program block:
• The channel-specific interface DB21, ... DBX7.1 (NC Start), which is usually controlled from the machine
control panel key NC Start, starts program execution in the same channel.
• With the NC instruction START, program execution in the first channel can be started from the second
channel, for example (for further information, see Section on Channel synchronization).
The START command can only be executed in AUTOMATIC and MDA modes. For this, the channel concerned
must be in the following state:
DB21, ... DBX35.7(channel status reset) or
DB21, ... DBX35.6 (channel status interrupted).
Table 9-5
Setting options
MD10711 =
0
1
2
3
4
Option
Function
Return value as the basic information (1st digit from the left)
0
0
2
1
0
1
0
1
0
2
2
2
1
0
1
1
2
2
2
2
2
0
1
2
1
0
1
0