Z1: NC/PLC interface signals
19.11 Spindles (S1)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1713
Signal state 0 or
edge change
1 → 0
Actual direction of rotation: Left
Signal irrelevant for
...
• Spindle is stationary: DB31, ... DBX61.4 (axis/spindle stationary) == 1
• Spindles without position measuring encoder
Corresponding to ...
DB31, ... DBX61.4 (axis/spindle stationary)
DB31, ...
DBX84.3
Rigid tapping active
Edge evaluation: yes
Signal(s) updated: Cyclic
The spindle is internally switched to axis mode by the "Rigid tapping" function (
G331
/
G332
). This
results in a reaction to or updating of the spindle-specific interface signals:
• DB31, ... DBX2.2 (spindle reset)
• DB31, ... DBX16.4 - DBX16.5 (synchronize spindle)
• DB31, ... DBX17.6 (invert M3/M4)
• DB31, ... DBX83.5 (spindle in setpoint range)
• DB31, ... DBX83.1 (programmable speed too high)
Signal state 1 or
edge change
0 → 1
• Rigid tapping active.
Application
example(s)
Notice!
If the following signals are set during rigid tapping, the thread will be destroyed:
• DB11, … DBX0.7 (mode group reset) = 1
• DB21, ... DBX7.7 (channel reset) = 1
• DB31, ... DBX2.1 (controller enable) = 0
• DB31, ... DBX8.3 (feed stop) = 1
DB31, ...
DBX84.5
Active spindle mode: Positioning mode
Edge evaluation: yes
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
Positioning mode (
SPOS
or
SPOSA
) is active.
Corresponding to ...
DB31, ... DBX84.7 (spindle mode control mode)
DB31, ... DBX84.6 (spindle mode oscillation mode)
DB31, ...
DBX84.6
Active spindle mode: Oscillation mode
Edge evaluation: yes
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
Oscillation mode is active.
Note: The spindle changes automatically to oscillation mode if there is a gear change.
Corresponding to ...
DB31, ... DBX84.7 (spindle mode control mode)
DB31, ... DBX84.5 (spindle mode positioning mode)
DB31, ... DBX82.3 (change gear)
DB31, ...
DBX83.7
Actual direction of rotation clockwise