5.3.2
Radial force loading
Point of application of radial forces F
RAS
at the shaft extension for:
● average operating speeds
● nominal bearing service life (L
10 h
) of 25000 h
)
5$6
[
Dimension
x:
Distance between the point of application of force F
RAS
and the shaft shoulder in mm
Figure 5-1
Force application point at the DE
Maximum permissible radial force on the S120M
3HUPLVVLEOHUDGLDOIRUFH
DWWKHVKDIW
>1@
5$6
)
Q PLQ
Q PLQ
Q PLQ
Q PLQ
Q PLQ
Q PLQ
Q PLQ
Q PLQ
Q PLQ
[>PP@
Figure 5-2
Maximum permissible radial force at S120M SH36 (article number: 6SL3532-6DF71)
S120M
5.3 Mechanical properties
Manual, 06/2019, 6SL3097-5AW00-0BP1
81
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......