F
u
nct
ion
d
ia
gr
am
s
Inter
nal contr
o
l/sta
tu
s wor
d
s
2-
82
4
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g.
2
-6
6
254
6 – Control word
, faults/alarms
- 2546 -
Function diagram
8
7
6
5
4
3
2
1
fp_2546_98_eng.vsd
DO: All objects
SINAMICS S110
27.10.08 V04.04.00
Internal control/status words - Control word, faults/alarms
11
12
13
14
15
Reserved
Control word, faults/alarms
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
= Acknowledge faults
Reserved
Reserved
PROFIdrive bit
9
10
8
7
6
5
4
3
2
1
0
Bit No.
r2138
STW faults/alarms
4000.00 μs
To fault buffer [8060.1]
r2138.7
This parameter refers to the Control Unit and is
used as source to simultaneously acknowledge
all faults on all drive objects.
<1>
These parameters refer to the Command Data Sets (CDS)
depending on the individual drive object (DO).
<2>
p2103[C]
1. Acknowledge
p2102[C]
Ackn all faults
<1>
<2>
p2112[C] (1)
p2116[C] (1)
p2117[C] (1)
p2106[C] (1)
p2107[C] (1)
p2108[C] (1)
p3111[C] (1)
p3112[C] (0)
T
0
p3110 [ms]
<2>
<1>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
1
1
1
1
1
1
To alarm buffer [8065.1]
r2138.11
To fault buffer [8060.1]
r2138.13
To fault buffer [8060.1]
r2138.14
To fault buffer [8060.1]
r2138.15
To alarm buffer [8065.1]
r2138.12
To alarm buffer [8065.1]
r2138.10
= External alarm 1 (A07850)
= External alarm 2 (A07851)
= External alarm 3 (A07852)
= External fault 1 (F07860)
= External fault 3 (F07862)
= External fault 2 (F07861)