1PH7 induction motors (Machine tools)
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
223
Information for using the motors
7
7.1
7.1
Transportation/storage before use
The motors should be stored indoors in dry, low-dust and low-vibration (v
rms
< 0.2 mm/s)
rooms. The motors should not be stored longer than two years at room temperature (+5° C
to +40° C) to retain the service life of the grease.
Observe the information provided in the operating instructions for transport and storage.
7.2
7.2
Ambient conditions
Operating temperature range: -15° C to +40° C (without any restrictions).
Storage: T = -20 °C to +70 °C
All of the catalog data refer to an ambient temperature of 40° C, mounted so that the motors
are not thermally insulated and an installation altitude up to 1000 m above sea level.
For conditions other than those specified above (ambient temperature > 40°C or installation
altitude > 1000 m above sea level), the permissible torque/power must be determined using
the factors from the following table. Ambient temperatures and installation altitudes are
rounded-off to 5° C or 500 m respectively.
Table 7- 1
Factors to reduce the torque/power (de-rating)
Ambient temperature in °C
Installation altitude
above sea level
40
45
50
1000
1.00
0.96
0.92
1500
0.97
0.93
0.89
2000
0.94
0.90
0.86
2500
0.90
0.86
0.83
3000
0.86
0.82
0.79
3500
0.82
0.79
0.75
4000
0.77
0.74
0.71
NOTICE
For ambient temperatures > 50 °C, please contact your local Siemens office.
Summary of Contents for SINAMICS S 1PH7
Page 1: ...SINAMICS Configuration Manual 04 2009 1PH7 Induction Motors for Machine Tools SINAMICS S s ...
Page 2: ......
Page 243: ......