2 Parameters
2.4 BICO parameters (connectors/binectors)
SINAMICS G120D
574
List Manual (LH14), 01/2016, A5E33842313
2.4
BICO parameters (connectors/binectors)
2.4.1
Binector inputs (BI)
Product: SINAMICS G120D, Version: 4707900, Language: eng, Type: BI
p0043
BI: Enable energy usage display / Enab energy usage
p0730
BI: CU signal source for terminal DO 0 / CU S_src DO 0
p0731
BI: CU signal source for terminal DO 1 / CU S_src DO 1
p0806
BI: Inhibit master control / PcCtrl inhibit
p0810
BI: Command data set selection CDS bit 0 / CDS select., bit 0
p0811
BI: Command data set selection CDS bit 1 / CDS select., bit 1
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
p0844[0...n]
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 S_src 1
p0845[0...n]
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 S_src 2
p0848[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 S_src 1
p0849[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 S_src 2
p0852[0...n]
BI: Enable operation/inhibit operation / Operation enable
p0854[0...n]
BI: Control by PLC/no control by PLC / Master ctrl by PLC
p0855[0...n]
BI: Unconditionally release holding brake / Uncond open brake
p0856[0...n]
BI: Enable speed controller / n_ctrl enable
p0858[0...n]
BI: Unconditionally close holding brake / Uncond close brake
p0860
BI: Line contactor feedback signal / Line contact feedb
p0897
BI: Parking axis selection / Parking axis sel
p1020[0...n]
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
p1021[0...n]
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
p1022[0...n]
BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
p1023[0...n]
BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
p1035[0...n]
BI: Motorized potentiometer setpoint raise / Mop raise
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
p1039[0...n]
BI: Motorized potentiometer inversion / MotP inv
p1041[0...n]
BI: Motorized potentiometer manual/automatic / Mop manual/auto
p1043[0...n]
BI: Motorized potentiometer accept setting value / MotP acc set val
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
p1108[0...n]
BI: Total setpoint selection / Total setp sel
p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir
p1113[0...n]
BI: Setpoint inversion / Setp inv
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG
p1140[0...n]
BI: Enable ramp-function generator/inhibit ramp-function generator / RFG enable
p1141[0...n]
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
p1142[0...n]
BI: Enable setpoint/inhibit setpoint / Setpoint enable
p1143[0...n]
BI: Ramp-function generator, accept setting value / RFG accept set v
p1201[0...n]
BI: Flying restart enable signal source / Fly_res enab S_src
p1230[0...n]
BI: DC braking activation / DC brake act
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
p1492[0...n]
BI: Droop feedback enable / Droop enable
p1501[0...n]
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
p1502[0...n]
BI: Freeze moment of inertia estimator / J_estim freeze
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation