2 Parameters
2.2 List of parameters
SINAMICS DCM
28
List Manual (LH8), 02/2015, 6RX1800-0ED76
2.2
List of parameters
Product: SINAMICS DC MASTER, Version: 4702900, Language: eng
Objects: CU_DC, CU_DC_R, CU_DC_R_S, CU_DC_S, DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31
Product: SINAMICS DC MASTER OA, Version: 1401800, Language: eng
Objects: DC_CTRL
Description:
Operating display for the Control Unit (CU).
Value:
0:
Operation
10:
Ready
20:
Wait for run-up
25:
Wait for automatic FW update of DRIVE-CLiQ components
31:
Commissioning software download active
33:
Remove/acknowledge topology error
34:
Exit commissioning mode
35:
Carry out first commissioning
70:
Initialization
80:
Reset active
99:
Internal software error
Notice:
For several missing enable signals, the corresponding value with the highest number is displayed.
Description:
Operating display for the drive.
Value:
0:
o0.0 No torque direction switched on
1:
o0.1 Torque direction I switched on
2:
o0.2 Torque direction II switched on
9:
o0.9 Wait for enable from master
10:
o1.0 Wait time for brake opening time running
11:
o1.1 Wait for operating enable at terminal 13
12:
o1.2 Wait for operating enable (signal source acc. to p0852)
13:
o1.3 Wait time after withdrawing a jog command running
14:
o1.4 Wait until the field has been reversed
15:
o1.5 Wait for operating enable from the optimization run
16:
o1.6 Wait for withdrawal of the immediate pulse inhibit
17:
o1.7 Wait for SINAMICS DCM connected in parallel in status o0.0
18:
o1.8 Operating state o1.8
19:
o1.9 Operating state o1.9
20:
o2.0 Wait for setpoint
21:
o2.1 Operating state o2.1
22:
o2.2 Operating state o2.2
30:
o3.0 Wait for the thyristor check to be completed
31:
o3.1 Wait for line supply symmetry
32:
o3.2 Wait for a DC contactor to pick up
33:
o3.3 Wait for the feedback signal "main contactor"
34:
o3.4 Operating state o3.4
35:
o3.5 Operating state o3.5
40:
o4.0 Wait for voltage at 1U1, 1V1, 1W1
41:
o4.1 Wait until fuse monitoring signals OK
42:
o4.2 Operating state o4.2
r0002
Control Unit operating display / CU op_display
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
-
Func. diagram:
2651
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 99
-
r0002
Drive operating display / Drv op_display
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
-
Func. diagram:
2651
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 129
-