SIMOTION P menu
SIMOTION P
Description
Temperature
Display of the temperatures in the device, monitoring of the threshold
value.
An alarm (Page 196) is issued when a threshold value is reached or
exceeded.
Set Diagnostic Switch
Diagnostic switch for recording diagnostic data and backing up the
non-volatile SIMOTION data on the external CFast card.
Diagnostics data can be recorded during power-up and during oper‐
ation for the error diagnostics. The diagnostics switch is automatically
reset after writing the data.
See also the following sections:
Recording diagnostic data (Page 181).
Backing up non-volatile SIMOTION data (retain data) (Page 166)
Webserver
Access to the SIMOTION IT Web server is protected by a multi-level
security concept.
Upon delivery, the security level is low to allow configuration of the
device.
The security state of the Web server can be set here.
The following selection options are available:
● Security Level: normal
● Security Level: low
Temperature specifications
Figure 8-4
Dialog Temperature
The temperature specifications for the SIMOTION P320-4 can be found at SIMOTION P >
Temperature.
The current, the minimum and the critical temperature are determined at the housing,
mainboard and CPU measuring points and displayed in this dialog box.
Operator Control (hardware)
8.1 SIMOTION P state application
SIMOTION P320-4 E / P320-4 S
124