![Siemens SIMOTICS XP 1MB155 Operating Instructions Manual Download Page 125](http://html.mh-extra.com/html/siemens/simotics-xp-1mb155/simotics-xp-1mb155_operating-instructions-manual_379082125.webp)
Maintenance
9.2 Corrective Maintenance
1MB155 / 1MB555
Operating Instructions, 03/2018, A5E41926185A
123
9.2.4
Shaft sealing, mounting dimension "L"
Shaft ∅
mm
x
mm
L
mm
Gamma ring
15 ... 25
6
8
30 ... 45
6.5
8.5
50 ... 100
7.5
9.5
Shaft ∅
mm
L
mm
V ring with protective cap
40 ... 65
11
70 ... 100
13.5
Make sure the sealing surface is free of dirt and damage.
Lightly grease the sealing lips.
9.2.5
Insulated roller bearings
If insulated rolling bearings are fitted, use insulated rolling bearings of the same type as
spare parts. This will prevent any bearing damage being caused by bearing currents.
9.2.6
O-ring seal
If O-ring seals are present, you should check that they are in perfect condition and that the
O-ring seals are properly seated in the grooves between the components. Replace damaged
O-ring seals.
O-ring seals can be present on the following components, for instance:
●
Adapters, tapers
●
Entries, glands
●
Bearing seals
●
End shield seals
●
Terminal box sealing
●
etc.
Summary of Contents for SIMOTICS XP 1MB155
Page 1: ......
Page 2: ......
Page 10: ...Table of contents 1MB155 1MB555 8 Operating Instructions 03 2018 A5E41926185A ...
Page 94: ...Start up 7 2 Switching on 1MB155 1MB555 92 Operating Instructions 03 2018 A5E41926185A ...
Page 108: ...Operation 8 6 faults 1MB155 1MB555 106 Operating Instructions 03 2018 A5E41926185A ...
Page 144: ...Service and Support 1MB155 1MB555 142 Operating Instructions 03 2018 A5E41926185A ...
Page 152: ......