9.3.4.2
Remove V ring for roller bearing seal
Depending on the particular version, there is a V ring. The V ring must be replaced if unusual
amounts of grease escape the roller bearing or the V ring is visibly damaged.
Figure 9-1
Remove the V ring
1. Mark the components so that they can be correctly assembled.
2. Remove the V ring
①
with the bearing cap – or by using a suitable tool from the shaft.
Removing the protective ring for IP56 degree of protection
The V ring for the outer bearing seal is fitted with a protective ring
②
for degree of protection
IP56. The protective ring does not have to be removed for disassembling the bearing bush.
● Remove the protective ring together with the V ring and the outer bearing cover or end
shield from the shaft.
See also
Fitting V ring for roller bearing seal (Page 87)
9.3.4.3
Fitting V ring for roller bearing seal
Requirement
The roller bearing is already fitted.
Maintenance
9.3 Corrective Maintenance
SIMOTICS HV C 1NA14544WA600AG0-Z
Operating Instructions 06/2018
87
Summary of Contents for Simotics HV C 1NA14544WA600AG0-Z
Page 2: ...14 06 2018 09 34 V3 00 ...
Page 10: ...Table of contents SIMOTICS HV C 1NA14544WA600AG0 Z 10 Operating Instructions 06 2018 ...
Page 74: ...Operation 8 9 Faults SIMOTICS HV C 1NA14544WA600AG0 Z 74 Operating Instructions 06 2018 ...
Page 100: ...Service and Support SIMOTICS HV C 1NA14544WA600AG0 Z 100 Operating Instructions 06 2018 ...
Page 104: ...Quality documents SIMOTICS HV C 1NA14544WA600AG0 Z 104 Operating Instructions 06 2018 ...
Page 106: ...Additional documents SIMOTICS HV C 1NA14544WA600AG0 Z 106 Operating Instructions 06 2018 ...
Page 110: ...Index SIMOTICS HV C 1NA14544WA600AG0 Z 110 Operating Instructions 06 2018 ...
Page 111: ......