Securing functional safety
2.3 Electrical installation of the encoder
BA 2730
14
Operating Instructions, 02/2021, A5E36448105A/RS-AG
Connection assignment incremental encoder IN 8.5834
Connector viewed from
the outside
Signal
Diagram showing the signals for clockwise
shaft rotation when viewing the clamping ring
and/or the motor drive end.
Power supply
Incremental signals
Connection
U
P
Sensor U
P
O V
Sensor O V
A+
A-
B+
B-
Flange socket
12 2
10
11
5
6
8
1
Sensor pins jumpered
in the encoder
Sensor pins jumpered
in the encoder
-
Connection assignment, absolute encoder IA 8.5883
Connector viewed from
the outside
Signal
①
0 absolute position value
②
Increasing absolute values
Diagram showing the signals for
clockwise shaft rotation when viewing
the clamping ring and/or the motor
drive end
Power supply
-
Incremental signals
Connection
U
P
Sensor U
P
O V Sensor O V Inner shield A+ A-
B+ B-
Flange socket (SSI) 7
1
10
4
11
15 16 12 13
Sensor pins
jumpered in the
connector
Sensor pins
jumpered in the
connector
Not available -
Absolute position values
Other signals
Connection
DATA DATA,
negated
CLOCK CLOCK,
negated
Direction of rotation Zeros
D+
D-
C+
C-
DIR
SET
Flange socket (SSI) 14
17
8
9
2
5
Absolute values are
counted down when
the input is
energized.
The absolute value
is set to zero when
the input is
energized.
Summary of Contents for SIMOGEAR BA 2730
Page 1: ......
Page 2: ......
Page 6: ...Table of contents BA 2730 4 Operating Instructions 02 2021 A5E36448105A RS AG ...
Page 28: ...Disposal BA 2730 26 Operating Instructions 02 2021 A5E36448105A RS AG ...
Page 29: ......
Page 30: ......