Service and maintenance
8.3 Checking and changing lubricants
BA 2030
88
Operating Instructions, 02/2021, A5E37880173A/RS-AM
8.3.10
Service life of the lubricants
Note
In case of ambient conditions deviating from normal conditions, e.g. high ambient
temperatures, high relative humidity, aggressive ambient media, the intervals between
changes should be shorter. In such cases, contact Technical Support for assistance in
determining the individual lubricant change interval.
Note
Oil sump temperatures above +80 °C can reduce service life. A temperature increase by 10 K
halves the service life by the amount as shown in the figure titled "Guide values for oil change
intervals".
For a +80 °C oil sump temperature, the following service life can be expected when observing
the properties specified by Siemens AG:
Table 8- 5
Service life of the oils
Type of oil
Service life
Mineral oil
10 000 operating hours or 2 years
Biodegradable oil
Physiologically safe oil according to USDA-H1/-H2
Synthetic oil
20 000 operating hours or 4 years
Summary of Contents for SIMOGEAR BA 2030
Page 1: ......
Page 2: ......
Page 68: ...Operation BA 2030 66 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 72: ...Faults causes and remedies BA 2030 70 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 104: ...Disposal BA 2030 102 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 206: ...Your suggestions BA 2030 204 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 207: ......
Page 208: ......