Service and maintenance
8.7 Replacing the vent valve
BA 2030
98
Operating Instructions, 02/2021, A5E37880173A/RS-AM
8.7
Replacing the vent valve
To ensure correct functioning, renew the breather valve yearly.
When replacing, prevent dirt and damaging atmospheres from entering the gearbox.
If too much oil is contained in the gearbox, oil will escape from the breather valve. Correct
the oil quantity and replace the breather valve.
8.8
Checking the oil level sensor (optional)
The oil level sensor indicates the oil level only when the gearbox is shut down.
Lower the oil level and fill it up again until the oil level sensor gives a switching signal.
Please refer to the separate operating instructions for the oil level sensor.
8.9
Cleaning the gearbox
WARNING
Explosion hazard due to overheating of the machine caused by a layer of dust
Deposits of dust have a thermally insulating effect, which can lead to the machine
overheating. The maximum surface temperature of the machine cannot be adhered to. Dust
can be ignited causing an explosion. This can result in death, serious injury or material
damage.
•
Regularly remove dust from the machine.
•
Do not allow dust layers thicker than 5 mm to build up.
•
Do not switch the machine on until the dust has been completely removed.
NOTICE
Dust deposits cause higher housing temperatures
Dust deposits prevent heat radiation.
Keep the geared motor free from dirt and dust.
Summary of Contents for SIMOGEAR BA 2030
Page 1: ......
Page 2: ......
Page 68: ...Operation BA 2030 66 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 72: ...Faults causes and remedies BA 2030 70 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 104: ...Disposal BA 2030 102 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 206: ...Your suggestions BA 2030 204 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 207: ......
Page 208: ......