Installation
4-2
SIMATIC VPU200–3104 Hardware Manual
4.1
VPU200 Voltage Conversion
The voltage requirement for the VPU200 can be changed to 120 or 240 volts
AC to meet local requirements. (See Figure 4-1) to change voltage:
1.
Turn the VPU200 so the back is facing you and the power cord
receptacle is to the left.
2.
Disconnect the power cord from the VPU200.
3.
To expose the fuse, slide the clear plastic panel so that it covers the
power cord receptacle.
4.
Remove the fuse by pulling upward on the black plastic lever.
5.
When the fuse lever is fully extended (and the fuse has been removed),
use needle-nose pliers to remove the small printed circuit board that is
mounted vertically next to the fuse holder.
6.
Rotate the printed circuit board so that the correct voltage will be
visible through the clear plastic panel and replace the board.
7.
Replace the fuse by pressing down on the black plastic lever.
8.
A grounded cord set must be used.
!
CAUTION
Use only a 3 AMP, 250 volt quick-acting fuse (Type AGC).
Use of non-recommended fuses could result in damage to equipment.
9.
Slide the clear plastic cover over the fuse and connect the power cord.