Technical specifications
5.4 Mechanical ambient conditions
Comfort Panels INOX PCT
Compact Operating Instructions, 05/2018, A5E38804191-AA
37
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
Sinusoidal interference
Test values
HF radiation (electromagnetic
fields) according to IEC 61000-4-3
80% amplitude modulation at 1 kHz
•
to 10 V/m from 80 MHz to 1 GHz
•
to 10 V/m from 1.4 GHz to 2 GHz
•
to 1 V/m from 2 GHz to 2.7 GHz
HF current feed on cables and
cable shields according to
IEC 61000-4-6
Test voltage 10 V with 80% amplitude modulation at 1 KHz in
the 10 KHz to 80 MHz range
Emission of radio interference
The following table shows the emitted interference from electromagnetic fields according to
EN 61000-6-4, measured at a distance of 10 m.
From 30 to 230 MHz
< 40 dB
(μV/m) quasi
-peak
From 230 to 1000 MHz
< 47 dB
(μV/m) quasi
-peak
See also
Notes about usage (Page 14)
5.4
Mechanical ambient conditions
5.4.1
Storage conditions
The following information is for a device that is transported and stored in its original
packaging.
The device meets the requirements according to IEC 60721-3-2 Class 2M2 with the following
amendments and limitations:
Type of condition
Permitted range
Free fall
≤ 1 m
Vibration according to IEC 60068-2-6
5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
250 m/s
2
, 6 ms, 1000 shocks