Table of contents
S7-300, CPU 31xC and CPU 31x: Installation
Operating Instructions, Edition 08/2004, A5E00105492-05
xi
Tables
Table 1-1
Ambient influence on the automation system (AS).................................................................... 1-1
Table 1-2
Galvanic isolation....................................................................................................................... 1-1
Table 1-3
Communication between sensors/actuators and the PLC......................................................... 1-2
Table 1-4
The use of local and distributed I/O ........................................................................................... 1-2
Table 1-5
Configuration consisting of the Central Unit (CU) and Expansion Modules (EMs) ................... 1-2
Table 1-6
CPU performance ...................................................................................................................... 1-3
Table 1-7
Communication .......................................................................................................................... 1-3
Table 1-8
Software..................................................................................................................................... 1-3
Table 1-9
Supplementary features............................................................................................................. 1-4
Table 3-1
S7-300 components:.................................................................................................................. 3-2
Table 4-1
Mounting rails - Overview .......................................................................................................... 4-4
Table 4-2
Module width.............................................................................................................................. 4-4
Table 4-3
Shielding terminals - Overview .................................................................................................. 4-5
Table 4-4
Interface modules - Overview .................................................................................................... 4-8
Table 4-5
Cabinet types ........................................................................................................................... 4-13
Table 4-6
Cabinet selection ..................................................................................................................... 4-15
Table 4-7
VDE specifications for the installation of a PLC system .......................................................... 4-16
Table 4-8
Measures for protective grounding .......................................................................................... 4-22
Table 4-9
Connecting the load voltage reference potential ..................................................................... 4-23
Table 4-10
Connecting the load voltage reference potential ..................................................................... 4-24
Table 4-11
Connecting the load voltage reference potential ..................................................................... 4-25
Table 4-12
Features of load power supply units ........................................................................................ 4-26
Table 4-13
Subnet nodes........................................................................................................................... 4-31
Table 4-14
MPI/PROFIBUS DP addresses................................................................................................ 4-31
Table 4-15
MPI addresses of CPs/FMs in an S7-300 system ................................................................... 4-32
Table 4-16
Operating modes for CPUs with two DP interfaces................................................................. 4-34
Table 4-17
Permissible cable length of a segment on the MPI subnet...................................................... 4-35
Table 4-18
Permissible cable length of a segment on the PROFIBUS subnet.......................................... 4-35
Table 4-19
Lengths of stub cables per segment........................................................................................ 4-36
Table 4-20
PG patch cord .......................................................................................................................... 4-36
Table 4-21
Available bus cables ................................................................................................................ 4-37
Table 4-22
Properties of PROFIBUS cables.............................................................................................. 4-37
Table 4-23
Marginal conditions for wiring interior bus cables.................................................................... 4-38
Table 4-24
Bus connector .......................................................................................................................... 4-38
Table 4-25
Data for twisted-pair patch cables............................................................................................ 4-55
Table 5-1
Module accessories ................................................................................................................... 5-2