background image

 

 

SIMATIC RF645T 

4

 

C79000-G8976-C477-01, 12/2017 

5

 

Technical specifications 

Table 5-1 

Technical specifications of SIMATIC RF645T 

 

 

6GT2810-2HC05 

Product designation 

SIMATIC RF645T 

 
Radio frequency 
Operating frequency (broadband) 

 

 

 

ETSI 

 

865 MHz to 868 MHz 

 

 

FCC, CMIIT and others 

 

902 MHz to 928 MHz 

 
Memory 
Chip (manufacturer/type) 

NXP UCode 7xm-2k 

Memory configuration 

 

 

 

EPC 

 

56 bytes / 448 bits 

 

 

User memory 

 

256 bytes / 2048 bits 

 

 

TID 

 

12 bytes / 96 bits 

Number of write cycles (< 40 °C) 

> 100 000 

Number of read cycles (< 40 °C) 

> 10

14

 

Data retention time (< 40 °C) 

20 years 

 
Electrical data 
Read range (on the metallic support) 

≤ 6 m 

1)

 

Protocol 

EPCglobal Class 1 Gen 2 / ISO 18000-63 

Transmission speed 

≤ 320 kbps

 

Polarization 

Linear (long side = polarization axis) 

 
Mechanical specifications 
Material 

Plastic (ABS) 

Silicone-free 

Yes 

Color 

Black 

Antenna material 

Aluminum 

Imprint 

No 

Summary of Contents for SIMATIC RF645T

Page 1: ...ce representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and s...

Page 2: ...PC 56 bytes 448 bits User memory 256 bytes 2048 bits Reading range 1 Up to 6 0 m Installation For mounting directly on metal surfaces 1 Depending on the environment the employed reader the antennas and the configured power 2 Ordering data Table 2 1 Ordering data Article number SIMATIC RF645T 6GT2810 2HC05 Mounting cover for SIMATIC RF645T 6GT2898 5AA00 Retaining bracket for SIMATIC RF645T 6GT2898 ...

Page 3: ...ne Perchloroethylene Acetone Alcohols Hot water hydrolysis resistance UV light and weathering Explanation of the rating Resistant Conditionally resistant Not resistant 4 Read write ranges Table 4 1 Read range between RF600 antennas and SIMATIC RF645T 1 Antenna type Read ranges RF620A 1 5 m RF640A 5 0 m RF642A 6 0 m RF650A 4 0 m RF660A 5 0 m RF680A 5 0 m 1 Ranges with max reader performance e g RF6...

Page 4: ...type NXP UCode 7xm 2k Memory configuration EPC 56 bytes 448 bits User memory 256 bytes 2048 bits TID 12 bytes 96 bits Number of write cycles 40 C 100 000 Number of read cycles 40 C 1014 Data retention time 40 C 20 years Electrical data Read range on the metallic support 6 m 1 Protocol EPCglobal Class 1 Gen 2 ISO 18000 63 Transmission speed 320 kbps Polarization Linear long side polarization axis M...

Page 5: ...istance to mechanical stress Not permitted Design dimensions and weight Dimensions L x W x H 52 0 5 36 0 5 12 5 mm Weight Approx 25 g Type of mounting Glued Mounting cover M4 Retaining bracket M5 1 Depending on the environment 2 The values for shock and vibration are maximum values and must not be applied continuously 6 Certificates and approvals Table 6 1 Certificates and approvals Labeling Descr...

Page 6: ...C477 01 12 2017 7 Dimension drawing All dimensions in mm SIMATIC RF645T Figure 7 1 Dimension drawing of SIMATIC RF645T Retaining bracket for SIMATIC RF645T Figure 7 2 Dimension drawing mounting cover 6GT2898 5AA00 for SIMATIC RF645T ...

Page 7: ...for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be precluded entirely we cannot guarantee full consistency However the information in this publication is reviewed regularly and any necessary corrections are included in subsequen...

Reviews: