SIMATIC RF630L Smartlabel
1.3 Memory configuration for smart labels with MLFBs -00, -01, -02
SIMATIC RF630L Smartlabel
Operating Instructions, 06/2009, J31069-D0186-U001-A4-7618
9
Reserved memory bank: programming or modifying memory areas
The memory areas of the reserved memory bank can be programmed using the SIMATIC
RF660R reader:
● Using the "tagDataWrite" XML command (see "SIMATIC RF660R Function Manual",
Section "Smart reader tag data writing")
Alternatively, the memory areas of the reserved memory bank can be modified using the
mobile RF610M reader:
● Using the "Write" function in the data editor (see "SIMATIC RF610M Operating
Instructions", Section "Write tag")
EPC memory bank: programming or modifying EPC ID
The memory area "Protocol Control Bit" is defined by the manufacturer and should not be
changed by the user.
The EPC ID can be programmed using the SIMATIC RF660R reader:
● Using the "tagProgramID" XML command (see "SIMATIC RF660R Function Manual",
Section "Smart reader tag ID programming")
Alternatively, the EPC ID can be modified using the mobile RF610M reader:
● Using the "Write ID" function (see "SIMATIC RF610M" Operating Instructions, Section
"Write ID"