Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
48
System Manual, 07/2017, J31069-D0227-U001-A9-7619
4.2.2
Minimum clearances
Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the
specified minimum distances must be multiplied by a factor of 1.5. The transponders
designed specifically for installation in/on metal are an exception to this.
Table 4- 15 Minimum clearances for transponders
RF210R
RF220R
RF240R
RF260R
RF280R
MDS D100
--
--
--
≥ 240
≥
420
MDS D117
≥ 15
--
--
--
--
MDS D124
≥ 25
≥ 40
≥ 90
≥ 180
≥
360
MDS D126
--
≥ 50
≥ 100
≥ 180
≥
400
MDS D127
≥ 15
--
--
--
--
MDS D139
--
--
--
≥ 200
≥
450
MDS D160
≥ 20
≥ 25
≥ 70
≥ 150
≥
300
MDS D165
--
--
--
≥ 240
≥
500
MDS D200
--
--
--
≥ 240
≥
500
MDS D261
--
--
--
≥ 200
≥
400
MDS D324
≥ 25
≥ 40
≥ 90
≥ 180
≥
360
MDS D339
--
--
--
≥ 200
≥
450
MDS D400
--
--
--
≥ 240
≥
500
MDS D421
≥ 10
--
--
--
--
MDS D422
≥ 15
≥ 20
≥ 50
--
--
MDS D423
--
--
≥ 80
≥ 160
≥
250
MDS D424
≥ 25
≥ 40
≥
90
≥ 180
≥ 360
MDS D425
≥ 20
≥ 25
≥ 75
--
≥
250
MDS D426
--
≥ 50
≥ 90
≥ 180
≥
400
MDS D428
≥ 25
≥ 25
≥ 75
≥ 150
≥ 300
MDS D460
≥ 20
≥ 25
≥ 70
≥ 150
≥ 300
MDS D521
≥ 10
--
--
--
--
MDS D522
≥ 15
≥ 20
≥ 50
--
--
MDS D522
Special vari-
ants
≥ 15
≥ 20
≥ 5
0
--
--
MDS D524
≥ 25
≥ 40
≥ 90
≥ 180
≥ 360
MDS D526
--
≥ 50
≥ 90
≥ 180
≥
400
MDS D528
≥ 25
≥ 25
≥ 75
≥ 150
≥ 300
All values are in mm, relative to the operating distance (S
a
) between reader and transponder, and
between transponder edge and transponder edge