3-10
PG 760 PII Programming Device
C79000-G7076-C766-01
You can connect the PG 760 PII to a SIMATIC S5 programmable controller
via the COM1/TTY interface port. The cable for establishing the connection
to the SIMATIC S5 CPUs is included with the PG 760 PII.
(Order No. 6ES5734-2BD20)
COM1
Figure 3-7
Connecting to the S5 Programmable Controller
Connect your PG 760 PII to a SIMATIC S5 programmable controller as
follows:
1. Switch off the PG 760 PII.
2. Plug the cable into the COM1/V.24 PLC interface port.
!
Caution
Risk of damage to the PG 760 PII!
The interface port may be damaged if you confuse the connections or use the
wrong connecting cables. Make sure the TTY cable of the PG 760 PII is
plugged into the COM1/TTY port and not into the LPT1 port.
Before plugging in the cables, you must discharge your body’s electrostatic
charge by briefly touching a grounded object (ESD guideline).
Use only the original cables to establish the connection to the programmable
controller.
The PG 760 PII and the programmable controller must be operated at the
same protective ground potential.
Connecting the
PG 760 PII to S5
Programmable
Controllers
Installing and Operating the PG 760 PII