Technical Specifications
5.2 Failsafe Alarm Relay Specifications
5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
2 A, 60 W
125 VDC
0.24 A, 30 W
125 VAC
0.5 A, 62.5 W
220 VDC
0.24 A, 60 W
250 VAC
0.25 A, 62.5 W
1500 V
rms
for 1 minute
5.3
Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RS900W:
Standard
10 Mbps
Ports
100 Mbps
Ports
1000 Mbps Ports
Notes
IEEE 802.3x
•
•
•
Full Duplex Operation
IEEE 802.3z
•
1000Base-LX
IEEE 802.3ab
•
1000Base-Tx
IEEE 802.1D
•
•
•
MAC Bridges
IEEE 802.1Q
•
•
•
VLAN (Virtual LAN)
IEEE 802.1p
•
•
•
Priority Levels
5.4
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RS900W.
Speed
10/100Base-TX
Connector
RJ45
FDX/HDX
Cable Type
> CAT 5
30
RUGGEDCOM RS900W
Installation Manual, 04/2021, C79000-G8976-1028-13