5.6
Wall mounting
Preparation
Note the position of the securing bar, see also section “Dimension drawings (Page 67)“.
When supplied, the securing bar is in the wall mounting position. You do not need to prepare the
device any further.
If the securing bar is in the rail mounting position, note the section “Changing the position of the
securing bar (Page 40)“.
Tools
To mount the device on a wall, you require the following:
• 2 wall plugs
• 2 fillister head screws
Note
Depending on the mounting surface, use suitable fittings.
Assembly
Note
The wall mounting must be capable of supporting at least four times the weight of the device.
To mount the device on a wall, follow the steps below:
1. Prepare the wall mounting with drilled holes and plugs. For the precise dimensions, refer to
the section "Dimension drawings (Page 67)".
2. Turn the upper screw in to the wall so that 10 mm remains jutting out.
3. Hang the device with the keyhole hanging mechanism on the rear on the screw.
4. Fix the device to the wall with the lower screw.
5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 43)".
installing and removing
5.6 Wall mounting
SCALANCE XCM-300
Product
Manual, 04/2022, C79000-G8976-C585-01
39
Summary of Contents for SIMATIC NET SCALANCE XCM-300
Page 6: ...Table of contents 6 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Page 12: ...Safety notices 12 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Page 58: ...Maintenance and cleaning 58 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Page 80: ...Certifications and approvals 80 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...