Technical specifications
6.1 Technical specifications
SCALANCE X-100
Operating Instructions, 04, A2B00060666D
57
Table 6- 5
Permitted cable lengths (fiber-optic)
Device type
SCALANCE
1 - 50 m
980/1000
plastic optical
fiber (POF)
1 - 100 m
200/230 polymer
cladded fiber (PCF)
6 dB max. permitted FO
cable attenuation with
3 dB link power margin
0 - 3,000 m
glass FOC
62.5/125 µm or
50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;
≥ 600 MHz
x
km;
6 dB max. permitted FO
cable attenuation with 3
dB link power margin
0 - 26000 m
glass FOC
10/125 µm single mode fiber;
0.5 dB/km at 1300 nm;
13 dB max. permitted FO
cable attenuation with 2 dB
link power margin
X104-2
-
-
+
-
X106-1
-
-
+
-
X108
-
-
-
-
X108PoE
-
-
-
-
X112-2
-
-
+
-
X116
-
-
-
-
X124
-
-
-
-
Table 6- 6
Aging time / learnable MAC addresses / MTBF
Device type
SCALANCE
Aging time
learnable MAC addresses
MTBF
X104-2
30 seconds
2048
134.87 years
X106-1
30 seconds
2048
136.65 years
X108
30 seconds
2048
139.83 years
X108PoE
30 seconds
2048
61.64 years
X112-2
30 seconds
8096
61.3 years
X116
30 seconds
8096
61.3 years
X124
30 seconds
8096
49.3 years
Table 6- 7
Permitted environmental conditions / EMC
Device type
SCALANCE
Operating temperature
Storage/transport
temperature
Relative
humidity in
operation
Operating altitude at max.
xx°C ambient temperature
X104-2
-10 to +60° C
-40 to +80° C
‹ 95 %
(no
condensation)
2000 m at max. 56° C
3000 m at max. 50° C
X106-1
-10 to +60° C
-40 to +80° C
‹ 95 %
(no
condensation)
2000 m at max. 56° C
3000 m at max. 50° C
X108
-20 to +70° C
-40 to +80° C
‹ 95 %
(no
condensation)
2000 m at max. 56° C
3000 m at max. 50° C
Summary of Contents for SIMATIC NET SCALANCE X-100 Series
Page 40: ...Product properties 3 12 Displays SCALANCE X 100 40 Operating Instructions 04 A2B00060666D ...
Page 54: ...Approvals and markings SCALANCE X 100 54 Operating Instructions 04 A2B00060666D ...
Page 62: ...References SCALANCE X 100 62 Operating Instructions 04 A2B00060666D ...
Page 72: ...Glossary SCALANCE X 100 72 Operating Instructions 04 A2B00060666D ...
Page 74: ...Index SCALANCE X 100 74 Operating Instructions 04 A2B00060666D U UL approval 6 ...