Technical Specifications
5.6 WLAN Specifications
Gain
• Maximum gain and uniform coverage in the high elevation
angle and zenith
• Gain in azimuth plane is not desired
Average 3D gain
> -5 dBi
Isolation between GNSS and
LTE Main (Primary)
> 10 dB in all uplink bands
Typical VSWR
< 2:5:1
Polarization
Any other than LHCP (Left-Hand Circular Polarized) is acceptable.
Vertical linear polarization is sufficient.
Gv and Gh are measured and averaged over -45 to 90° in elevation, and ± 180° in azimuth.
5.6
WLAN Specifications
Supported Standards
IEEE 802.11a
IEEE 802.11b
IEEE 802.11g
IEEE 802.11n
Maximum Throughput
TCP: 80 Mbps at 2.4 GHz
UDP: 100 Mbps at 2.4 GHz
Diversity
2.4 GHz MRC support for extended range
5.0 GHz diversity capable
Host Interface
4-Bit SDIO
Maximum EIRP
< 200 mW at 5250 to 5350 MHz
5.7
Operating Environment
The RUGGEDCOM RX1400 is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Storage
Temperature
-40 to 85°C (-40 to 185 °F)
Ambient Relative
5% to 95%
Maximum Altitude
2000 m (6562 ft)
Maximum Altitude
2000 m (6562 ft)
Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
Operating temperature may vary based on the limitations of installed SFPs. Refer to the
RUGGEDCOM
SFP Transceivers Catalog
for SFP temperature ratings.
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
Non-condensing
RUGGEDCOM RX1400
Installation Manual, 01/2021, C79000-G8976-1103-17
43