Device Management
3.2 Configuring the Device
Pin
Name
Description
8
CTS
Clear To Send
9
Reserved (Do Not Connect)
The management port is a 10/100Base-TX copper Ethernet port with an RJ45
connector. The following is the pin-out for the management port:
8
1
Figure 3.2
RJ45 Management Port
Pin
Name
Description
1
TX+
Transmit Data+
2
TX-
Transmit Data-
3
RX+
Receive Data+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
RX-
Receive Data-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Communication Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RSG2488F console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RSG2488F is
If connecting to the management port, use the address
For more information about available ports, refer to
Note
Single-mode fiber ports only support Ultra Physical Contact (UPC) cable connectors.
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured.
All configuration management is done via the RUGGEDCOM RSG2488F interface.
For more information about configuring the device, refer to the
RUGGEDCOM ROS-F
Configuration Manual
associated with the installed software release.
22
RUGGEDCOM RSG2488F
Installation Manual, 07/2021, C79000-G8976-1351-07