Technical Specifications
5.5 Fiber Optic Ethernet Port Specifications
5.5
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered
with the RUGGEDCOM RSG2300.
10FL Ethernet Optical Specifications
Tx (dBm)
Mode
Connector
Type
Cable
Type (µm)
Tx λ
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
Power
Budget
(dB)
MM
ST
62.5/125
850
-16
-9
-34
-11.2
2
18
MM
ST
50/125
850
-19.8
-12.8
-34
-11.2
2
14.2
Typical.
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and
number of splices. Consult a Siemens sales associates when determining maximum distances.
Fast Ethernet (10/100 Mbps) Optical Specifications
Tx (dBm)
Mode
Connector
Type
Cable
Type (µm)
Tx λ
(nm)
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
Power
Budget
(dB)
MM
ST
62.5/125
1300
-19
-14
-31
-14
2
12
MM
ST
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
SC
62.5/125
1300
-19
-14
-31
-14
2
12
MM
SC
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
MTRJ
62.5/125
1300
-19
-14
-31
-14
2
12
MM
MTRJ
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
LC
62.5/125
1300
-19
-14
-32
-14
2
13
SM
ST
9/125
1310
-15
-8
-32
-3
20
17
SM
SC
9/125
1310
-15
-8
-31
-7
20
16
SM
LC
9/125
1310
-15
-8
-34
-7
20
19
SM
SC
9/125
1310
-5
0
-34
-3
50
29
SM
LC
9/125
1310
-5
0
-35
3
50
30
SM
SC
9/125
1310
0
5
-37
0
90
37
SM
LC
9/125
1310
0
5
-37
0
90
37
Typical.
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and
number of splices. Consult a Siemens sales associates when determining maximum distances.
Gigabit Ethernet (1 Gbps) Optical Specifications
Note
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20
to 85 °C (-4 to 185 °F) operation only.
RUGGEDCOM RSG2300
Installation Manual, 04/2022, C79000-G8976-1046-18
33