Technical Specifications
5.7 Operating Environment
Copper Serial Ports
Baud Rate
300 to 230 kbps
Connector
DB9 or RJ45
Isolation
2.5 kV
Fiber Serial Ports
Mode
Multimode
Connector
ST
Typical Distance (km)
5
Optical Wavelength
(nm)
820
Cable Size
50/125 or 62.5/125
5.7
Operating Environment
The RUGGEDCOM RS910W is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
5% to 95%
Maximum Altitude
2000 m (6562 ft)
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Non-condensing.
5.8
Mechanical Specifications
Weight
1.2 kg (2.7 lbs)
Ingress Protection
IP30
Enclosure
20 AWG Galvanized Steel
5.9
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
34
RUGGEDCOM RS910W
Installation Manual, 04/2021, C79000-G8976-1031-12