Certification
6.1.6 ISO
6.1.6
ISO
This device was designed and manufactured using a certified ISO (International
Organization for Standardization) quality program that adheres to the following
standard:
•
ISO 9001:2015
Quality management systems – Requirements
6.1.7
RoHS
This device is declared by Siemens AG to meet the requirements of the following
RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831
6.1.8
Other Approvals
This device meets the requirements of the following additional standards:
•
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS900GPF has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
20 V/m
x
IEC
61000-4-4
Burst (Fast Transient)
Signal Ports
± 2 kV
3
RUGGEDCOM RS900GPF
Installation Manual, 01/2021, C79000-G8976-1353-05
33