Technical Specifications
4.4 Supported Networking Standards
Note
• All optical power numbers are listed as dBm averages. To convert from average
to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens Sales associate when
determining maximum segment distances.
Wavelength (nm)
Transmit
Power (dBm)
Data
Rate
Mode Connector Cable
(μm)
Transmit Receive
Min
Max
Receiver
Sensitivity
(dBm)
Receiver
Saturation
(dBm)
Distance
10 Mbps
MM
ST
62.5/125
820
820
—
—
-33.7
-9
0.7
10 Mbps
MM
ST
62.5/125
820
820
-16
-9
—
—
0.7
100
Mbps
MM
MTRJ
62.5/125
1300
1300
-19
-14
-31
-14
2.5
100
Mbps
MM
LC
62.5/125
1300
1300
-19
-14
-32
-14
2
100
Mbps
SM
LC
9/125
1300
1300
-15
-8
-33
-8
15
SM
ST
9/125
1310
1310
-29
-12
—
—
—
10 Mbps
SM
ST
9/125
1310
1310
—
—
-36
-17
—
Typical.
Operating temperature: 0 to 70 °C (32 to 158 °F)
4.4
Supported Networking Standards
Note
The RUGGEDCOM RMC features Link Pass Through support. When loss of link
is detected on either the fiber side or the copper side, link pulses are no longer
transmitted on any of the RUGGEDCOM RMC ports. This feature allows for prompt
loss of link detection and user correction.
Parameter
10Base-FL
100Base-FX
Notes
IEEE 802.3
Yes
10Base-T
IEEE 802.3u
Yes
100Base-TX/100Base-FX
4.5
Operating Environment
Parameter
Range
Comments
Ambient Operating
Temperature
-40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius
surrounding the center of the enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
20
RUGGEDCOM RMC
Installation Manual, 04/2021, C79000-G8976-1006-10