Edition
04/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM M2200F
https://www.siemens.com/ruggedcom
Page 1: ...Edition 04 2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M2200F https www siemens com ruggedcom ...
Page 2: ...ed Ethernet Switches RUGGEDCOM M2200F Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1343 09 ...
Page 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...
Page 4: ...4 1 5 3 Supported Fiber Optic Cables 4 1 6 Tamper Evident Security Seals 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device to a Panel 10 2 4 Connecting the Failsafe Alarm Relay 11 2 5 Connecting Power 12 2 5 1 Connecting AC or DC Power 13 2 5 2 Wiring Examples 15 3 Device Manageme...
Page 5: ...et Port Specifications 27 5 6 Operating Environment 27 5 7 Mechanical Specifications 27 5 8 Dimension Drawings 28 6 Certification 31 6 1 Approvals 31 6 1 1 CSA 31 6 1 2 European Union EU 31 6 1 3 FCC 32 6 1 4 FDA CDRH 32 6 1 5 ISED 33 6 1 6 ISO 33 6 1 7 RoHS 33 6 1 8 Other Approvals 33 6 2 EMC and Environmental Type Tests 34 iv RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 6: ...7148 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM M2200F is available online at https support industry siemens com To request or inquire a...
Page 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...
Page 8: ...s and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 ...
Page 9: ...Preface Contacting Siemens viii RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 10: ...Loss technology 40 to 85 C 40 to 185 F operating temperature no fans Conformal coated printed circuit boards optional 18 AWG galvanized steel enclosure Universal Power Supply Options Fully integrated dual redundant optional power supplies Universal high voltage range 88 300 VDC or 85 264 VAC Popular low voltage ranges 24 VDC 10 36 VDC 48 VDC 36 72 VDC Screw or pluggable terminal blocks for reliabl...
Page 11: ...nk detected Green Solid 100 Mbps Green Blinking 1000 Mbps Orange Solid 10 Mbps Speed Off No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs i e Status Duplex or Speed Mode Button The Mode button sets the display mode for the port status indicator LEDs i e Status Duplex or Speed It can also be used to res...
Page 12: ...ironment Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contac...
Page 13: ...munication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summarizes the relevant cabling standards Cabling Category 1000Base TX Compliant Required Action 5 No New wiring infrastructure required 5 Yes Verify TIA EIA 568 A compliance 5e Yes No action required New installations should be designed with Category 5e or higher 6 Yes No action...
Page 14: ...curity seals provide evidence of unauthorized tampering or removal of components NOTICE Worn damaged or missing seals must be replaced immediately Replacement seals are available for purchase from Siemens For more information contact a Siemens Sales representative There are three ways to determine if a security seal has been tampered with The seal is cut or torn A pattern is left on the device whe...
Page 15: ...Introduction 1 6 Tamper Evident Security Seals 6 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 16: ...dures other than those specified herein may result in hazardous radiation exposure NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate...
Page 17: ...the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damaged contact Siemens for assistance 2 3 Mounting the Device The RUGGEDCOM M2200F is designed for maximum mounting and display flexibility It can be equipped with...
Page 18: ...ng ambient temperature of the rack may be higher than the ambient temperature of the room Make sure the rack is installed in a suitable environment that can withstand the maximum ambient temperature generated by the rack Make sure each device in the rack is separated by at least one rack unit of space or 44 mm 1 75 in to promote convectional airflow Forced airflow is not required However any incre...
Page 19: ...ccessible install the rack mount adapters at the front of the chassis Note The chassis features multiple mounting holes allowing the rack mount adapters to be installed up to 25 mm 1 in from the face of the device 1 2 3 3 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required install adapters on the opposite side of the device to protect from vibrations 3 Insert the devic...
Page 20: ...m conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM M2200F One common application for this relay is to signal an alarm if a power ...
Page 21: ...nnections under severe shock or vibration NOTICE Electrical hazard risk of damage to the device Make sure power input to the device is within the specified input range For information about the nominal input range for the device refer to Power Supply Specifications Page 25 Note For maximum redundancy in a dual power supply configuration use two independent power sources Use minimum 16 gage copper ...
Page 22: ...ssis ground and must be removed in order to avoid damage to transient suppression circuitry during testing NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 24 or 48 VDC power supply Damage to the power supply may occur IMPORTANT Each internal power module is labeled POWER 1 or POWER 2 Make sure to connect the power supply to the corresponding internal power ...
Page 23: ... Terminal 7 Chassis Ground Terminal 8 Chassis Ground Connection Figure 2 4 Terminal Block Wiring 5 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 6 Install the supplied metal jumper between terminals 2 4 and 6 to connect the surge ground terminals to the chassis ground terminal The surge ground terminals are used as the ground conductor for...
Page 24: ... 2 6 32 Screw 3 6 Ring Lug Figure 2 5 Chassis Ground Connection DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied terminal block cover is always installed before the device is powered 8 Install the terminal block cover 2 5 2 Wiring Examples The following illustrate how to connect power to single and dual power supplies RUGGEDCOM M2...
Page 25: ...Installing the Device 2 5 2 Wiring Examples Figure 2 6 Single AC Power Supply Figure 2 7 Single DC Power Supply 16 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 26: ...Installing the Device 2 5 2 Wiring Examples Figure 2 8 Dual AC Power Supply Figure 2 9 Dual DC Power Supply RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 17 ...
Page 27: ...Installing the Device 2 5 2 Wiring Examples Figure 2 10 Dual AC DC Power Supply 18 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 28: ... to RUGGEDCOM M2200F s console and Web interfaces NOTICE The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Description ...
Page 29: ...h and access the RUGGEDCOM M2200F console and Web interfaces via the device s IP address For more information about available ports refer to Communication Ports Page 21 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM M2200F interface For more information about configuring the device re...
Page 30: ...RUGGEDCOM M2200F chassis Slot 5 supports a one port fiber or copper Ethernet module up to 1 Gbps All other ports support any combination of fiber or copper Ethernet connectors up to 1 Gbps The exact configuration of the device can be determined by reading the factory data file through the RUGGEDCOM M2200F user interface For more information about how to read the factory data file refer to the RUGG...
Page 31: ...nshielded twisted pair UTP cables with Micro D male connectors The Micro D connectors are directly connected to the chassis ground on the device and can accept CAT 5 shielded twisted pair STP cables Pin Out The following is the pin out description for the Micro D connectors 1 6 Figure 4 3 Micro D 10 100 1000Base TX Port Pin Configuration Name Pin 10 100Base TX 1000Base TX Description 1 RX BI_DA Re...
Page 32: ...ctional Pair D Specifications For specifications on the available copper Ethernet ports refer to Copper Ethernet Port Specifications Page 26 4 2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either LC Lucent Connector SC Standard or Subscriber Connector or ST Straight Tip connectors Make sure the Transmit Tx and Receive Rx connections of each port are properly connected ...
Page 33: ... 4 2 Fiber Optic Ethernet Ports For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Ethernet Port Specifications Page 27 24 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 34: ...5 250 VDC d 88 VDC 300 VDC 2 A T HI 110 230 VAC d 85 VAC 264 VAC 2 A T 28 W a F denotes fast acting fuse b T denotes time delay fuse c Power consumption varies based on configuration 10 100Base TX ports consume roughly 1 W less than fiber optic ports d The HI power supply is the same power supply for both AC and DC 5 2 Failsafe Relay Specifications Maximum Switching Voltage 250 VAC 125 VDC Rated S...
Page 35: ...fications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM M2200F Note Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances All optical power numbers are listed as dBm averages F51 transceivers are rated ...
Page 36: ...abling is duplex type unless specified otherwise b Typical c All optical power numbers are listed as dBm averages d Typical distance The maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associates when determining maximum segment distances 5 6 Operating Environment The RUGGEDCOM M2200F is rated to operate und...
Page 37: ...e All dimensions are in millimeters unless otherwise stated Note Dimensional tolerances are in accordance with ISO 2768 mK unless otherwise stated 285 49 438 15 313 18 44 45 0 8 Figure 5 1 Overall Dimensions 28 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 38: ...ons 5 8 Dimension Drawings 479 29 314 7 308 10 28 96 51 05 25 40 11 68 32 77 461 0 6 35 31 75 9 9 6 35 470 4 21 08 12 70 Figure 5 2 Rack Mount Dimensions RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 29 ...
Page 39: ...ications 5 8 Dimension Drawings 44 5 368 0 325 6 309 6 293 4 259 1 86 4 172 7 11 4 23 4 7 4 467 4 275 6 51 3 482 6 Figure 5 3 Panel Mount Dimensions 30 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 40: ...d with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements The Certificate Body CB test certificate is available on SIOS at https support industry siemens com cs ww en view 109794212 6 1 2 European Union EU This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1...
Page 41: ...sonable protection against harmful interference when the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which c...
Page 42: ...stricted use of certain hazardous substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 8 Other Approvals This device meets the requirements of the following additional standard...
Page 43: ...iption Test Levels Severity Levels Enclosure Contact 8 kV IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m Note a Signal Ports 4 kV 2 5 kHz Note a DC Power Ports AC Power Ports IEC 61000 4 4 Burst Fast Transient Earth Ground Ports 4 kV 4 Signal Ports 4 kV Line to Ground 2 kV Line to Line 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5...
Page 44: ... s 100 for 0 05 s Signal Ports 2 kV Fail Safe Relay Output DC Power Ports 2 kV Dielectric Strength AC Power Ports 2 kV Signal Ports 5 kV Fail Safe Relay Output DC Power Ports IEC 60255 5 HV Impulse AC Power Ports 5 kV a Siemens specified severity levels EMC Immunity Type Tests per IEEE 1613 Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber E...
Page 45: ...est Levels Severity Level IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60068 21 1 Vibration 2g 10 150 Hz IEC 60068 21 2 Shock 30 g 11 ms IEC 60068 2 78 Humidity Damp Heat Steady State Test Cab 10 days 55 C 131 F and 93 Relative Humidity IEC 6006...
Page 46: ...ic Field DC Magnetic Exposure Section 070 Part 1 MIL STD 810F Low Pressure Altitude Storage Low Pressure Altitude Operational High Temperature Storage High Temperature Operational Low Temperature Storage Low Temperature Operational Temperature Shock Storage Humidity Acceleration Salt Fog and Vibration Method 500 Series Procedures MIL STD 1275B Power Quality Per Standard RUGGEDCOM M2200F Installati...
Page 47: ...Certification 6 2 EMC and Environmental Type Tests 38 RUGGEDCOM M2200F Installation Manual 04 2022 C79000 G8976 1343 09 ...
Page 48: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...