Montageanleitung für / Assembly Instructions for IE RJ45 Plug PRO (6GK1901-1BB10-6AA0)
Copyright © 2010 Siemens AG
15. Open the cover of the contact holder.
16. Place the wires in the guide slots
according to the colored markers on the
contact holder.
17. Contact the wires by pressing down the
cover with a tool or hard object.
18. Align the cable so that the shield foil lies
between the shield clips of the contact
holder.
19. Push the sealing ring into the rear wall
and screw the forcing nut over
it loosely.
20. Turn the rear wall so that the latch is on
the same side as the RJ-45 release catch.
21. Push the contact holder into the rear wall
as far as the limit stop. The limit stop must
not jut out over the cover of the contact
holder!
22. Secure the position of the contact holder
by tightening the forcing nut.
23. Push the housing over the contact holder.
The latch of the rear wall must be on the
same side as the labeling of the housing.
24. Press the rear wall into the housing until it
clicks into place audibly.
Avoid pressing on the seal around the
rear wall.
25. Tighten the forcing nut completely.
Opening the plug:
1. To open the plug, lever the catch in the
housing towards the side wall with a
slotted screwdriver.
2.
Pull the rear wall out of the housing by the
cable while holding down the screwdriver.
Notes:
Replace the knife cassette if the cut edges
become ragged or after approx
1500 operations on cables with PVC
outer jackets
150 operations on cables with PUR
outer jackets
The piercing contacts of the IE RJ45 Plug
PRO can be released and recontacted up to
10 times.
Cable ends that have already been pierced
must not be used again but must be cut off.
Do not remove the plug by pulling on it!
To create a connecting cable with crossover
wires, arrange the wires at one end of the
cable according to the color scheme below:
Connect white with yellow
Connect blue with orange
For more information on setting up networks, refer to the SIMATIC NET Industrial Ethernet Network Manual