Product Information/Installation Instructions CP 5613 A2, CP 5614 A2
Product Information/Installation Instructions CP 5613 A2, CP 5614 A2
A5E00779184
39
PROFIBUS
Values
Connector to PROFIBUS
9-pin sub D female connector with screw lock-
ing mechanism. (The CP 5614 A2 has two in-
terfaces. Due to lack of space, no angled bus
connectors can be used.)
The following network components are recom-
mended for attachment to PROFIBUS:
●
Bus connector RS 485,
order number 6GK1500-0EA01
●
Bus terminal 12M,
order number 6GK1500-0AA10
Type of transmission
RS 485 floating within the SELV limits
Transmission rate
9.6 Kbps to 12 Mbps
Mode of the PROFIBUS inter-
face
Floating (interface signals)
Non-floating (cable shield)
PROFIBUS controller used
●
CP 5613 A2/CP 5614 A2 master:
ASPC2R ST E2a
●
CP 5614 A2 slave: DPC31
Electromagnetic
Compatibility
Values
Noise emission
complying with EN 55022 = CISPR 22
●
Limit class B
●
FCC Class B
Noise immunity on signal lines
+/-2 kV to EN 61000-4-5 , surge
Immunity to electrostatic dis-
charge
+/-6 kV, Contact discharge complying with EN
61000-4-2
Immunity to high-frequency
interference
●
10 V/m at
80 MHz to 2 GHz complying with EN 61000-
4-3
●
10 V/m 50 % on duration at 900 MHz and
1.89 GHz
complying with EN 61000-4-3
●
10 V/m at 80 % amplitude modulation and 1
kHz,
9 kHz to 80 MHz complying with EN 61000-
4-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com