Application and functions 

 

1.5 Compatibility with previous product 

 

CP 443-5 Extended 

26

 

Manual, 11/2018, C79000-G8976-C162-09 

Summary of Contents for SIMATIC NET CP 443-5 Extended

Page 1: ..._______ ___________________ ___________________ SIMATIC NET S7 400 PROFIBUS CP 443 5 Extended Manual Manual Part B 11 2018 C79000 G8976 C162 09 Preface Application and functions 1 Displays and mode selector 2 Installation and commissioning 3 Notes on operation 4 Technical specifications 5 Approvals A References B ...

Page 2: ...e operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING...

Page 3: ...e following products CP 443 5 Extended Article number 6GK7443 5DX05 0XE0 Hardware product version 1 Firmware version V7 1 8 Communications processor for connection of SIMATIC S7 400 S7 400H to PROFIBUS CP 443 5 Extended Article number 6AG1443 5DX05 4XE0 Hardware product version 1 Firmware version V7 1 8 Communications processor for connection of SIMATIC S7 400 S7 400H to PROFIBUS ...

Page 4: ...h every CP or on the Internet at the following address Link https support industry siemens com cs ww de view 1158693 Manual Part B manual S7 CPs for PROFIBUS CP 443 5 Extended this manual Purpose of the manual This manual describes the properties of this device and shows application examples The manual supports you when installing connecting up and commissioning the device The required configurati...

Page 5: ...tworks against cyber threats it is necessary to implement and continuously maintain a holistic state of the art industrial security concept Siemens products and solutions constitute one element of such a concept Customers are responsible for preventing unauthorized access to their plants systems machines and networks Such systems machines and components should only be connected to an enterprise ne...

Page 6: ...the WEEE directive 2012 19 EU Waste Electrical and Electronic Equipment Do not dispose of the product at public disposal sites For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact Keep to the local regulations You will find information on returning the product on the Internet pages of Siemens In...

Page 7: ...ynchronization 21 1 4 7 Data record routing 22 1 4 8 Use in faulttolerant systems 22 1 4 9 Other characteristics 23 1 5 Compatibility with previous product 24 1 5 1 Extended functionality compared with previous product 24 1 5 2 Replacing older modules module replacement 25 2 Displays and mode selector 27 3 Installation and commissioning 29 3 1 Important notes on using the device 29 3 1 1 Notes on ...

Page 8: ...ble of contents CP 443 5 Extended 8 Manual 11 2018 C79000 G8976 C162 09 B References 41 B 1 On configuring and using the CP 41 B 2 On installing and commissioning the CP 42 B 3 On programming 43 Index 45 ...

Page 9: ...owing communication services in the standard and H systems PROFIBUS DP with the following characteristics DP master class 1 redundant operation in faulttolerant system also possible Direct data exchange DP slave to DP slave As a DP master the CP 4435 Extended is capable of enabling direct data exchange for its DP slaves SYNC FREEZE The outputs or inputs can be synchronized by the user program usin...

Page 10: ...ke it out of operation when necessary while the system is running In other words you can configure and activate additional DP slaves or DP slots while the S7 station is in RUN Enabling disabling DP slave in the standard system DP slaves can be activated and deactivated by the user program using system function SFC12 Diagnostics requests As a DP master class 1 the CP 4435 supports diagnostics reque...

Page 11: ...ent LAN The timeofday synchronization frame must be forwarded over PROFIBUS for the synchronization of further stations The CP supports time stamping of distributed process signals in conjunction with the IM 153 Timeofday status value standard daylight saving time switchover synchronization status Data record routing You can use the CP as a router for data records intended for field devices for ex...

Page 12: ...mum 4 DP masters CP 443 5 Extended maximum 10 Multicomputing is supported except with CiR and H systems System environment The CP 4435 Extended is supported by the S7 400 CPUs and CPU operating systems with the order numbers and versions listed in the table below From the table you can see which functionality is supported when you use the CP 4435 Extended V 6 1 with the various CPU types The follo...

Page 13: ...y a b c d e CPU412 412 1XF04 0AB0 as of V4 0 24 24 as of V4 1 24 24 CPU412 2 412 2XG04 0AB0 as of V4 0 24 24 as of V4 1 24 24 CPU414 2 414 2XG04 0AB0 as of V4 0 24 24 as of V4 1 24 24 CPU414 3 414 3XJ04 0AB0 as of V4 0 24 24 as of V4 1 24 24 CPU414 4H 414 4HJ04 0AB0 as of V4 0 24 24 as of V4 0 5 24 24 CPU416 2 416 2XK04 0AB0 as of V4 0 64 64 as of V4 1 64 64 CPU416 3 416 3XL04 0AB0 as of V4 0 64 6...

Page 14: ...6ES7 412 1XF02 0AB0 2 or higher 12 12 CPU 413 6ES7 413 1XG01 0AB0 2 or higher 12 12 6ES7 413 1XG02 0AB0 1 or higher 12 12 CPU 413 2 6ES7 413 2XG01 0AB0 2 or higher 12 12 6ES7 413 2XG02 0AB0 1 or higher 12 12 CPU 414 1 6ES7 414 1XG01 0AB0 2 or higher 12 12 6ES7 414 1XG02 0AB0 2 or higher 12 12 CPU 414 2 128 KB 6ES7 414 2XG01 0AB0 2 or higher 12 12 6ES7 414 2XG02 0AB0 2 or higher 12 12 CPU 414 2 384...

Page 15: ... 2FK02 0AB0 as of V4 0 64 64 CPU 417 4 417 4XL00 0AB0 as of V3 1 64 64 CPU 417 4H 417 4HL00 0AB0 as of V2 1 64 64 417 4HL01 0AB0 as of V3 1 64 64 Legend The characteristic is supported the listed mode is possible The characteristic is not supported the listed mode is not possible 1 All CPUs are capable of CiR the H CPUs HCiR 1 3 3 Project engineering Configuration and downloading the configuration...

Page 16: ...sions for all module types You will find information on the current block versions and the current blocks to download from the Internet in our Customer Support at the following address Link https support industry siemens com cs ww en ps 15677 pm With older module types this recommendation assumes that you are using the latest firmware version for the particular module type Program blocks for open ...

Page 17: ...STEP 7 configuration software For the permitted values refer to Table 7 1 in Section 7 Page 35 Note Remember the cable length The permitted cable length must be kept to depending on the transmission speed Refer to the information in 4 Page 42 1 4 2 Characteristic data of the DP interface General characteristic data No special program blocks are required for DP mode The interfacing to the distribut...

Page 18: ...assigned parameters When a high value is configured for the constant bus cycle time in the network properties of the PROFIBUS DP line CiR functionality The numbers of connections etc shown in Table General characteristic data of DP mode Page 17 also apply to the entire DP master system if there is a configured DP slave expansion CiR functionality If you specify the properties of a CiR object in th...

Page 19: ...ycle load time due to FDL connections The calculation of the cycle load time for FDL connections is largely dependent on the time required to execute the program blocks AG_SEND AG_RECV on the S7400 CPU The following table lists the cycle load times of the available FCs in milliseconds A distinction is made between the statuses job completed and job active The entries relate to the run time in the ...

Page 20: ... example for routing Note PG or HMI functions or data record routing If PG or HMI functions or data record routing are used a suitable number of S7 connections must be reserved during configuration Help provided by STEP 7 The number of connections on PROFIBUS shown in the table above can vary due to other influencing factors The STEP 7 configuration tool displays warnings and help messages as soon...

Page 21: ...om a DP slave corresponds to SFC59 in terms of function SFB53 WRREC Write data record to a DP slave corresponds to SFC58 in terms of function SFB54 ALARM Read interrupt information from a DP slave call in an interrupt OB 1 PNO PROFIBUS Users Organization 1 4 6 Time of day synchronization The CP 4435 forwards timeofday synchronization frames in the following directions 1 From the CPU via the CP to ...

Page 22: ...artner or You can implement redundant and single peripheral structures mixed mode is also possible You will find more detailed information about the possible operating and structural options in the manual 2 Page 42 If the CP 4435 Extended is used in a faulttolerant S7400H system the following communications services can also be used on single nonredundant connections S7 connection including PG fun...

Page 23: ...ust also be deleted otherwise the data will become inconsistent Special feature of the DP mode If the CPU is in RUN mode at the same time the memory reset is rejected by the CP DP diagnostics frames when the CPU is in STOP All diagnostic frames from DPV0 standard slaves and all DP alarm frames from DP S7 DP V1 standard slaves arriving when the CPU is in STOP mode are handled as follows In S7 compa...

Page 24: ...duced loading time with FWL_FAST_LOAD To load new firmware use only the new function for fast loading To do this select the following entry for the interface parameter assignment of your PC PG in the firmware loader CPxxx FWL_FAST_LOAD By using this function the time required for loading firmware is reduced significantly compared with the old function Note CPxxx FWL cannot be used The setting CPxx...

Page 25: ...used up to now Configuration procedure 6GK7 443 5DX00 0XE0 6GK7 443 5DX01 0XE0 6GK7 443 5DX02 0XE0 6GK7 443 5DX03 0XE0 6GK7 443 5DX04 0XE0 Configuration unchanged replacing a defective module If you have no requirements beyond what you had with the previous CP you do not need to make changes in the configuration All you need to do is replace the hardware with the power supply turned off Extending ...

Page 26: ...Application and functions 1 5 Compatibility with previous product CP 443 5 Extended 26 Manual 11 2018 C79000 G8976 C162 09 ...

Page 27: ...status of the CP Table 2 1 Legend meaning of the symbols Symbol Status ON steady light OFF Flashing Any INTF LED EXTF LED BUSF LED RUN LED STOP LED CP operating mode Starting up STOP RUN Running RUN Stopping RUN STOP Stopped STOP STOP with internal error or memory reset Waiting for firmware update duration 10 sec onds after power on Waiting for firmware update CP currently has an incomplete firmwa...

Page 28: ...ing the mode selector Controlling the mode There are different ways in which you can control the mode of the CP 443 5 Extended as follows Mode selector STEP 7 special diagnostics configuration software To control the CP mode from STEP 7 the mode selector must be set to RUN Mode selector With the mode selector you can set the following modes Change from STOP to RUN The CP loads configured and or do...

Page 29: ...n an environment with pollution degree 1 or 2 see IEC 60664 1 WARNING The equipment is designed for operation with Safety Extra Low Voltage SELV by a Limited Power Source LPS This means that only SELV LPS complying with IEC 60950 1 EN 60950 1 VDE 0805 1 must be connected to the power supply terminals The power supply unit for the equipment power supply must comply with NEC Class 2 as described by ...

Page 30: ...ly the Siemens DIN rail 6ES5 710 8MA11 may be used to mount the modules WARNING Requirements for the cabinet enclosure To comply with EU Directive 94 9 ATEX95 the enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529 WARNING Cable If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C special precautions must be tak...

Page 31: ...nt is suitable for use in Class I Zone 2 Group IIC or non hazardous locations only 3 2 Installation and commissioning NOTICE Do not pull or plug the CP while power is on The CP 443 5 Extended must not be pulled or plugged while the power is connected In some cases this could lead to damage of the module If you do pull or plug the CP while power is on the CPU changes to STOP Afterwards the power fo...

Page 32: ... using the universal rack as an extension rack you require an IM with a communication bus link Step Procedure significance 2 Connection to PROFIBUS Refer to 1 Page 41 3 Project engineering Depending on the communication services being used configuration involves the following steps Node initialization This is necessary in all cases This assigns a PROFIBUS address and bus pa rameters to the PROFIBU...

Page 33: ...g function in the configuration tool 2 Turn the power supply to the S7 station on and off again Bus fault of the type bus short circuit If there is a bus short circuit this can cause one of the following responses on the PROFIBUS subnet Failure of the bus line Failure of stations of all stations The response can be recognized by evaluating with OB86 Note Bus fault statistics With STEP 7 special di...

Page 34: ...ad system diagnostics SFC13 read out standard diagnostics 4 3 Display of the the DP slave history Restricted display of older diagnostics data in STEP 7 special diagnostics Diagnostics data can be read out in STEP 7 special diagnostics With an additional button you can also have older diagnostics data displayed alongside the current diagnostics data With the CP 443 5 Extended DX05 it is possible t...

Page 35: ...n From the S7 400 backplane bus 0 6 A typical at 5 V Power dissipation 3 W Permitted ambient conditions Operating temperature Transport storage temperature Relative humidity Operating altitude 0 C to 60 C 40 C to 70 C maximum 95 at 25 C up to 2000 m above sea level Degree of protection IP 20 Construction Dimensions W x H x D mm 25 x 290 x 210 Weight Approx 650 g In addition to this all the informa...

Page 36: ...Technical specifications CP 443 5 Extended 36 Manual 11 2018 C79000 G8976 C162 09 ...

Page 37: ...nt and the Council of 26 February 2014 on the approximation of the laws of the member states concerning equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96 29 03 2014 pages 309 356 2014 30 EU EMC EMC directive of the European Parliament and of the Council of February 26 2014 on the approximation of the laws of the member states rela...

Page 38: ...60079 15 Explosive atmospheres Part 15 Equipment protection by type of protection n Ex ec IIC T4 Gc Certificate IECEx DEK 18 0019X Applied standards EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements EN 60079 7 Explosive Atmospheres Part 7 Equipment protection by increased safety e You can see the current versions of the standards in the IECEx certificate that you will find on ...

Page 39: ...ased safety e The current versions of the standards can be seen in the EC Declaration of Conformity see above ATEX approval II 3 G Ex nA IIC T4 Gc The conditions must be met for the safe deployment of the CP according to the section Notes on use in hazardous areas according to ATEX IECEx Page 30 You should also note the information in the document Use of subassemblies modules in a Zone 2 Hazardous...

Page 40: ... file E85972 NRAG NRAG7 cULus Hazardous Classified Locations Underwriters Laboratories Inc cULus IND CONT EQ FOR HAZ LOC Applied standards ANSI ISA 12 12 01 CSA C22 2 No 213 M1987 APPROVED for Use in Cl 1 Div 2 GP A B C D T4 Cl 1 Zone 2 GP IIC T4 Ta Refer to the temperature class on the type plate of the CP Report UL file E223122 NRAG NRAG7 Note the conditions for the safe deployment of the CP acc...

Page 41: ...ion in the Siemens Industry Mall at the following address Link https mall industry siemens com Manuals on the Internet You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support Link https support industry siemens com cs ww en ps 15661 man Go to the required product in the product tree and make the following settings Entry type Manuals Manuals on the data medium You...

Page 42: ...n System S7 400 M7 400 Siemens AG Installation Installation manual Link https support industry siemens com cs ww en view 1117849 Module data Reference manual Link https support industry siemens com cs ww en view 1117740 4 SIMATIC NET PROFIBUS Network Manual Siemens AG SIMATIC NET Manual Collection Link https support industry siemens com cs ww en view 35222591 5 SIMATIC Modifying the System during ...

Page 43: ...ort industry siemens com cs ww en view 21407212 B 3 On programming 7 SIMATIC NET Program blocks for SIMATIC NET S7 CPs Programming Manual Siemens AG Link https support industry siemens com cs ww en view 62543517 8 SIMATIC System and Standard Functions for S7 300 400 Programming manual Siemens AG Link https support industry siemens com cs ww en view 1214574 ...

Page 44: ...References B 3 On programming CP 443 5 Extended 44 Manual 11 2018 C79000 G8976 C162 09 ...

Page 45: ...a record routing 11 28 Degree of protection 35 35 Diagnostics data Display of older 34 Diagnostics requests 10 18 Direct data exchange 9 Disposal 6 DP diagnostics frames when the CPU is in STOP 23 DP master class 1 9 DP slave 10 Activate deactivate 12 DPV1 23 DPV1 functionality 13 14 E Electromagnetic compatibility 35 Environmental conditions 35 ET 200M I O devices 13 F FAQs on the Internet 34 FDL...

Page 46: ... class 35 R Recycling 6 Replacing a module 24 25 Replacing a module without a programming device 11 Router 9 Routing 11 RUN 23 28 S S7 communication 11 16 S7 connections 11 19 Safety notices 29 SEND RECEIVE interface 12 SIMATIC NET glossary 6 Slot 32 Special diagnostics 28 34 Startup parameters 18 STEP 7 4 STEP 7 Professional 15 STEP 7 V5 5 15 STOP 23 28 SYNC FREEZE 9 12 Synchronization interval 2...