background image

 

SIMATIC NET 

Operating Instructions 

Release 11/2020 

English 

 

ANT896-4MA (Omni-Antenna 0.7 / 2.7 GHz) 

 

SIMATIC NET antenna for use in GSM(2G), UMTS(3G) and LTE(4G) 

networks 

Copyright © Siemens AG 2020 

All rights reserved 

The reproduction, transmission or use of this document or its con-

tents is not permitted without express written authority. Offenders 

will be liable for damages. All rights, including rights created by 

patent grant or registration of a utility model or design, are re-

served. 

Disclaimer of Liability 

We have checked the contents of this manual for agreement with 

the hardware and software described. Since deviations cannot be 

precluded entirely, we cannot guarantee full agreement. However, 

the data in this manual are reviewed regularly and any necessary 

corrections included in subsequent editions. Suggestions for im-

provement are welcome. 

Technical data subject to change without prior notice. 
Siemens AG 

Digital Industries 

Postfach 48 48 

D-90026 NÜRNBERG 

GERMANY 

Security information 

In order to protect plants, systems, machines and networks against 

cyber threats, it is necessary to implement –  and continuously 

maintain  –  a holistic, state-of-the-art industrial security concept. 

Siemens’ products and solutions constitute one element of such a 

concept. For more information about industrial security, please visit  
https://www.siemens.com/industrialsecurity 

Recycling and disposal 

The products are low in pollutants, can be recycled and meet 

the re-quirements of the WEEE directive 2012/19/EU for the 

disposal of electrical and electronic equipment. 
Do not dispose of the products at public disposal sites. 

For environmentally friendly recycling and the disposal of 

your old device contact a certified disposal company for electronic 

scrap or your Siemens contact 

https://support.industry.siemens.com/cs/ww/en/view/109479891. 

Note the different national regulations. 

Warning notice system 

This manual contains notices you have to observe in order to ensure 

your personal safety, as well as to prevent damage to property. The 

notices referring to your personal safety are highlighted in the manual 

by a safety alert symbol, notices referring only to property damage have 

no safety alert symbol. These notices shown below are graded accord-

ing to the degree of danger. 

 DANGER 

indicates that death or severe personal injury 

will

 result if proper precau-

tions are not taken. 

 

 WARNING 

indicates that death or severe personal injury 

may

 result if proper pre-

cautions are not taken. 

 

 CAUTION 

indicates that minor personal injury can result if proper precautions are 

not taken. 

 

NOTICE 

indicates that property damage can result if proper precautions are not 

taken. 

Qualified Personnel 

The product/system described in this documentation may be 

operated only by 

personnel qualified

  for the specific task in 

accordance with the relevant documentation, in particular its 

warning notices and safety instructions. Qualified personnel are 

those who, based on their training and experience, are capable of 

identifying risks and avoiding potential hazards when working with 

these products/systems.

 

7  Safety notes 

 

 WARNING 

Danger due to lightning strikes 

Antennas installed outdoors must be within the area covered by a light-

ning protection system.  
Make sure that all conducting systems entering from outdoors can be 

protected by a lightning protection potential equalization system. 
When implementing your lightning protection concept, make sure you 

adhere to the VDE 0182 or IEC 62305 standard. 

 

NOTICE 

Improper use 

The device (and its components) may only be used for the application 

described in the catalog or the operating instructions. Combinations with 

devices or components of other manufacturers are permitted it they have 

been approved by Siemens.  
Correct and safe operation of the device is guaranteed only when it is 

transported, stored, set up, installed, used and maintained according to 

the recommendations. 

8  Components of the product 

The following components are supplied with the 

ANT896-4MA: 

  1 ANT896-4MA Antenna 

  Operating Instructions 

Please check that the consignment you have received is 

complete. If it is not complete or there are signs of external 

damage, please contact your supplier or your local Siemens 

office. 

9  Installation 

5.  Remove the antenna from the protective foil. 
6.  Place the antenna on the connector of the device and 

slightly screw the union nut of the antenna onto the con-

nector. 

7.  Align the antenna in the desired position und tighten the 

union nut. 

8.  To reposition the antenna, loosen the union nut by half a 

turn, position the antenna and retighten the union nut. 

C79000-8974-C374-03 

Summary of Contents for SIMATIC NET ANT896-4MA

Page 1: ...ng eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden VORSICHT bedeutet dass eine leichte Körperverletzung eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden ACHTUNG bedeutet dass Sachschaden eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden Beim Auftreten mehrerer Gefährdungsstufen wird immer der Warn hinwe...

Page 2: ...ahlungswinkel 360 Impedanz 50 Ω Anschluss SMA Connector male Gewicht 44 g Farbe Schwarz Schutzart IP54 Lagertemperatur 40 C 85 C Transporttemperatur 40 C 85 C Betriebstemperatur 40 C 85 C RoHS 2002 95 EC Erfüllt Silikonfrei Ja 5 Maßbild Abmessungen in Millimeter 6 Felddiagramme Horizontal 700 MHz Vertikal 700 MHz Horizontal 2400 MHz Vertikal 2400 MHz ...

Page 3: ...se notices shown below are graded accord ing to the degree of danger DANGER indicates that death or severe personal injury will result if proper precau tions are not taken WARNING indicates that death or severe personal injury may result if proper pre cautions are not taken CAUTION indicates that minor personal injury can result if proper precautions are not taken NOTICE indicates that property da...

Page 4: ...Impedance 50 Ω Connector SMA Connector male Weight 44 g Colour Black Degree of protection IP54 Storage temperature 40 C 85 C Transport temperature 40 C 85 C Operation temperature 40 C 85 C RoHS 2002 95 EC Compliant Silicone free Yes 11 Dimension drawing Dimensions in millimeter 12 Radiation pattern Horizontal 700 MHz Vertical 700 MHz Horizontal 2400 MHz Vertical 2400 MHz ...

Reviews: