background image

SIMATIC NET 

Compact Operating Instructions 

Release 05/2019 

English 

ANT793-8DQ  

(Right circular polarized antenna 5.8 GHz) 

SIMATIC NET antenna for use in WLAN networks in harsh environ-

ments, tunnels, mining, elevator shafts, etc. 

Copyright © Siemens AG 2019  

      All rights reserved 

The reproduction, transmission or use of this document or its contents is 

not permitted without express written authority. Offenders will be liable for 

damages. All rights, including rights created by patent grant or registration 

of a utility or design, are reserved. 

Disclaimer of liability 

We have checked the contents of this manual for agreement with the 

hardware and software described. Since deviations cannot be preclud-ed 

entirely, we cannot guarantee full agreement. However, the data in this 

manual are reviewed regularly and any necessary corrections included in 

subsequent editions.  
Technical data subject to change without prior notice. 
Siemens AG 

Digital Industries 

Postfach 48 48 

D-90026 NÜRNBERG

GERMANY

Security information 

In order to protect plants, systems, machines and networks against cyber 

threats, it is necessary to implement –  and  continuously maintain –  a 

holistic, state-of-the-art industrial security concept. Siemens’ products and 

solutions constitute one element of such a concept. For more information 

about industrial security, please visit  
https://www.siemens.com/industrialsecurity 

Recycling and disposal 

The products are low in pollutants, can be recycled and meet 

the re-quirements of the WEEE directive 2012/19/EU for the 

disposal of elec-trical and electronic equipment. 
Do not dispose of the products at public disposal sites. 
For environmentally friendly recycling and the disposal of your 

old device contact a certified disposal company for electronic scrap or 

your Siemens contact 

https://support.industry.siemens.com/cs/ww/en/view/109479891. 
Note the different national regulations. 

Warning notice system 

This manual contains notices you have to observe in order to ensure your 

personal safety, as well as to prevent damage to  property. The notices 

referring to your personal safety are highlighted in the manual by a safety 

alert symbol, notices referring only to property damage have no safety 

alert symbol. These notices shown below are graded according to the 

degree of danger. 

 DANGER 

indicates that death or severe personal injury 

will

 result if proper precau-

tions are not taken. 

 WARNING 

indicates that death or severe personal injury 

may

 result if proper pre-

cautions are not taken. 

 CAUTION 

indicates that minor personal injury can result if proper precautions are 

not taken. 

NOTICE 

indicates that property damage can result if proper precautions are not 

taken. 

Qualified Personnel 

The product/system described in this documentation may be operat-ed 

only by 

personnel qualified

 for the specific task in accordance with the 

relevant documentation, in particular its warning notices and safety 

instructions. Qualified personnel are those who, based on their training 

and experience, are capable of identifying risks and avoiding potential 

hazards when working with these products/systems.

1  Safety notes 

 WARNING 

Danger due to lightning strikes 

Antennas installed outdoors must be within the area covered by a light-

ning protection system.  
Make sure that all conducting systems entering from outdoors can be 

protected by a lightning protection potential equalization system. 
When implementing your lightning protection concept, make sure you 

adhere to the VDE 0182 or IEC 62305 standard. 

NOTICE 

Improper use 

The device (and its components) may only be used for the application 

described in the catalog or the operating instructions. Combinations with 

devices or components of other manufacturers are permitted it they have 

been approved by Siemens.  
Correct and safe operation of the device is guaranteed only when it is 

transported, stored, set up, installed, used and maintained according to 

the recommendations. 

2  Components of the product 

The following components are supplied with the antenna: 

1x antenna with 1x N-connector female

1x fastening set for mast mounting consisting of

-

1x mounting bracket

-

1x tensioning clamp

-

1x U-bolt

-

2x screw nuts and 2x spring washers for fastening the antenna

to the mounting bracket

-

2x screw nuts and 2x spring washers for fastening the mounting

bracket to the mast

1x Compact Operating Instructions

Please check that the consignment you have received is complete. If it is 

not complete or there are signs of external damage, please contact your 

supplier or your local Siemens office. 

3   Mast mounting 

Note for SCALANCE W

7

00 

Special requirements for the USA and Canada 

Per device only one antenna may be connected.  To connect the antenna, 

use the antenna connectors R1A1, R1A2 or R2A1, R2A2. 

Note for SCALANCE W1700 
Antenna connector 

The antenna can only be used on one antenna connector (R1A1 or R2A1) 

per WLAN interface. The remaining antennas must be fitted with a termi-

nating resistor. 

C79000-G8974-C500-03 

Summary of Contents for SIMATIC NET ANT793-8DQ

Page 1: ...deutet dass Tod oder schwere Körperverletzung eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden VORSICHT bedeutet dass eine leichte Körperverletzung eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden ACHTUNG bedeutet dass Sachschaden eintreten kann wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden Qualifiziertes Personal ...

Page 2: ...LANCE W Gerät nicht im Lieferumfang enthalten an die N Connect Anschlussbuchse der Antenne an Das maximale Anzugsmoment für die Überwurfmuttern beträgt 1 5 Nm 10 Richten Sie die Antenne durch Bewegen entlang des ovalen Bohr lochs am Montagewinkel in gewünschte Position aus Ziehen Sie die Schraubenmuttern fest Das Anzugsmoment beträgt 7 0 Nm 11 Schützen Sie die Anschlüsse vor Umwelteinflüssen z B m...

Page 3: ... are not taken WARNING indicates that death or severe personal injury may result if proper pre cautions are not taken CAUTION indicates that minor personal injury can result if proper precautions are not taken NOTICE indicates that property damage can result if proper precautions are not taken Qualified Personnel The product system described in this documentation may be operat ed only by personnel...

Page 4: ...nector socket of the antenna The maximum tightening torque for the union nuts is 1 5 Nm 10 Align the antenna to the desired position by moving it along the oval hole on the mounting bracket Tighten the nuts The tightening torque is 7 0 Nm 11 Protect the connectors from environmental influences e g with self vulcanizing adhesive tape or a shrink on hose 4 Technical data Electrical data Frequency ra...