4 Connecting
up
!
Warning
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a
lightning protection system. Make sure that all conducting systems
entering from outdoors can be protected by a lightning protection
potential equalization system.
When implementing your lightning protection concept, make sure you
adhere to the VDE 0182 or IEC 62305 standard.
A suitable lightning conductor is available in the range of accessories
of SIMATIC NET Industrial WLAN:
Lightning protector LP798-1N (order no. 6GK5798-2LP00-2AA6)
!
Warning
Danger due to lightning strikes
Installing this lightning protector between an antenna and a
SCALANCE W7xx is not adequate protection against a lightning
strike. The LP798-1N lightening protector only works within the
framework of a comprehensive lightning protection concept. If you
have questions, ask a qualified specialist company.
Procedure
Remove the protective cap from the N connector of the antenna and
screw on the antenna.
Operating Instructions (compact) ANT793-8DN
31
A5E01116928B-01