Image processing
4.2 Code verification
SIMATIC MV420 / SIMATIC MV440
68
Operating Instructions, 04/2013, A5E02371045-06
4.2.8.1
Standard report for Siemens DPM
Note
Grades and evaluations in the standard report for Siemens DPM
The standard report for Siemens DPM only ever contains the grades and evaluations whose
quality characteristics are activated in the adjustment support.
With the default setting, activated quality characteristics include all characteristics except for
"Symbol contrast" and "Cell size".
Field name (TAG)
Value
Verification type (Qt)
5
If the exposure settings do not comply with the
standard: F
Evaluation (Qs)
3 (Good), 2 (Fair) or 1 (Poor)
Overall grade (Q0)
4, 3, 2, 1 or 0
Contrast grade (Q1)
4, 3, 2, 1 or 0
Contrast (q1)
0 ... 100
Axial non-uniformity grade (Q2)
4, 3, 2, 1 or 0
Axial non-uniformity (q2)
0.00 ... 1.00
Unused error correction grade (Q4)
4, 3, 2, 1 or 0
Unused error correction (q4)
0.00 ... 1.00
Cell modulation grade (Q6)
4, 3, 2, 1 or 0
Cell modulation 1 (q6)
0 ... 100
Cell modulation 2 (q6)
0 ... 100
Print growth grade (Q9)
4, 3, 2, 1 or 0
Print growth X (q9)
-100 ... 100
Print growth Y (q9)
-100 ... 100
Cell size grade (Q10)
4, 3, 2, 1 or 0
Cell size (q10)
0.0 ... 99.9 mil
Center offset grade (Q19)
4, 3, 2, 1 or 0
Center offset (q19)
0.0 ... 99.9
Size offset grade (Q20)
4, 3, 2, 1 or 0
Size offset (q20)
0.0 ... 99.9
Border match grade (Q21)
4, 3, 2, 1 or 0
Border match (q21)
0 ... 100
Angle of distortion grade (Q22)
4, 3 or 0
Angle of distortion (q22)
-45 ... 45.0
ECCLevel (q14)
200
Height (q15)
0 ... 9.99 inches
Width (q16)
0 ... 9.99 inches
Angle (q17)
0 ... 360°
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Page 423: ......