Technical data
SIMATIC MV320 (as of FS: A3)
28
Operating Instructions, 03/2021, C79000-G8976-C643-01
6GF3320-0HT01
Permitted ambient conditions
Degree of protection
IP54
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +65 °C
Humidity
5 ... 95%, no condensation
Impact resistance
Resistant to being dropped repeatedly on con-
crete from a height of 1.8 m
Resistant to ambient light
Up to 96 890 lux
Dimensions and weight
Dimensions (L x W x H)
77 x 52 x 132 mm
Weight
116 g
Color
Dark gray
Read distances
The read distances are made up of a wide field and a near field.
•
All code patterns must be of high quality and on a physical midline at an angle of 10°
when read.
•
The table refers to the AGC factory settings; accuracy: ± 10 %
Table 8- 1
Read distances
Test code
Min. mm
Max. mm
3 mil Code 39
85
107
7.5 mil Code 39
18
167
10.5 mil GS1 DataBar
5
205
13 mil Code 128
13
265
5 mil Data Matrix
28
100
6.3 mil Data Matrix
18
135
10 mil Data Matrix
5
165
20.8 mil Data Matrix
13
328
1 mil = 0.0254 mm
The ideal read distance is about 100 mm. Depending on the code type and code size, smaller
or larger distances are possible.
Summary of Contents for SIMATIC MV320
Page 6: ...Preface SIMATIC MV320 as of FS A3 6 Operating Instructions 03 2021 C79000 G8976 C643 01 ...
Page 10: ...Safety notes SIMATIC MV320 as of FS A3 10 Operating Instructions 03 2021 C79000 G8976 C643 01 ...
Page 18: ......
Page 30: ......
Page 32: ......
Page 38: ......