5.6 Possible errors when powering on
Mobile Client900WXN
66
Operating Instructions, 04/2015, A5E35883103-AB
5.6
Possible errors when powering on
The following 2 errors are typical:
●
There is an internal error
If an internal error occurs during device start-up, the "SF" LED lights up red.
Switch the device off and on again.
●
The device does not start
If the device does not start, the operating temperature is outside the permitted range
according to the section "Problem solving (Page 86)". This is displayed as follows:
–
The "TEMP" LED lights up red.
–
The "PWR" LED flashes at 3 Hz.
The device is in the "Power-on delay" state. The device switches on automatically as
soon as the operating temperature is in the permitted range. Wait until the permitted
operating temperature has been reached. This is displayed as follows:
- The "PWR" LED lights up green.
- The "TEMP" LED flashes at 3 Hz.
Additional causes of errors are available in the section "Problem solving (Page 86)".