Technical specifications
8.7 Description of Active Management Technology
SIMATIC IPC547E
130
Operating Instructions, 02/2014, A5E32317120-AB
8.7.2
Overview of AMT
This section describes the required measures and settings on the local IPC so that the IPC
can be controlled and maintained remotely from a management station known below as the
help desk PC.
The local IPC is known below as the "AMT PC".
The sections contain the following information:
●
AMT settings in the MEBx and in the BIOS setup
●
Basic configuration of AMT
●
Further useful notes
8.7.3
Activate AMT
For security reasons, AMT is not enabled on new devices.
Procedure
1.
Connect the AMT PC by means of "Create Internet connection" when using the
corresponding LAN controller (LAN 1).
2.
If necessary, first reset AMT to the default status.
You can find the required information in the chapter "Reset AMT with Unconfigure ME
(Page 132)".
3.
To access the BIOS, press the <F2> key while the device is booting.
4.
In the Advanced menu, enable "Intel AMT Support", and "Intel AMT Setup Prompt".
5.
Exit the BIOS with the <F10> key "Save and Exit".
The AMT PC starts.
6.
To access the MEBx, press the <Ctrl+P> keyboard shortcut at system power-up.
7.
In the login dialog, enter the standard password "admin".
Summary of Contents for SIMATIC IPC547E
Page 4: ...Preface SIMATIC IPC547E 4 Operating Instructions 02 2014 A5E32317120 AB ...
Page 22: ...Overview 1 5 Status displays SIMATIC IPC547E 22 Operating Instructions 02 2014 A5E32317120 AB ...
Page 142: ...List of abbreviations SIMATIC IPC547E 142 Operating Instructions 02 2014 A5E32317120 AB ...
Page 154: ...Index SIMATIC IPC547E 154 Operating Instructions 02 2014 A5E32317120 AB ...