Installing/mounting
5.1 Permitted mounting positions
SIMATIC IPC427C
26
Operating Instructions, 04/2009, A5E02414743-01
Suspended
Operation with CompactFlash card and/or SSD drive and
without expansion modules:
0 to +40°C
Note:
Mounting brackets are required if the device is suspended.
Upright mounting
Permitted temperatures
Operation with hard disk:
•
with up to 3 expansion modules
(max. load 9 W): +5 to +40°C
With installed Compact Flash card:
•
without expansion modules: 0 to +45°C
Operation with CompactFlash card and/or SSD drive:
•
with up to 3 expansion modules
(max. load 9 W) in RAL: 0 to +45°C
Operation with Compact Flash cards:
•
with up to 3 expansion modules
(max. load 9 W) in RAL: 0 to +50°C
RAL = Restricted Access Location
(e.g. installation of the unit in a lockable cabinet)
NOTICE
The safety and installation instructions for the expansion modules should be followed if the
device is expanded with PCI-104 / PC/104-plus modules.
If necessary, the device should be installed in an enclosure that meets the requirements of
paragraphs 4.6 and 4.7.3 of IEC/UL/EN/DINEN60950-1.