background image

 

 

Safety Guidelines 

Safety Guidelines 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

DANGER 

 

indicates that death or severe personal injury will result if proper precautions are not taken. 

WARNING 

 

indicates that death or severe personal injury may result if proper precautions are not taken. 

CAUTION 

 

with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. 

CAUTION 

 

without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. 

NOTICE 

 

indicates that an unintended result or situation can occur if the corresponding information is not taken into 

account. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The device/system may only be set up and used in conjunction with this documentation. Commissioning and 

operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes 

in this documentation qualified persons are defined as persons who are authorized to commission, ground and 

label devices, systems and circuits in accordance with established safety practices and standards. 

Prescribed Usage 

Note the following: 

WARNING 

 

This device may only be used for the applications described in the catalog or the technical description and only 

in connection with devices or components from other manufacturers which have been approved or 

recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, 

positioning and assembly as well as careful operation and maintenance. 

Trademarks 

All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this 

publication may be trademarks whose use by third parties for their own purposes could violate the rights of the 

owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

 

 

Siemens AG 
Automation and Drives 
Postfach 48 48 
90327 NÜRNBERG 
GERMANY 

 Ordernumber: A5E01208363-01  
Ⓟ 08/2007 

Copyright © Siemens AG 2007. 
Technical data subject to change

Summary of Contents for SIMATIC IM 153-2

Page 1: ...s IM 153 2 Interface Module ______________ ______________ ______________ Introduction 1 Description 2 Technical specifications 3 SIMATIC DP PA Link and Y Link bus links IM 153 2 Interface Module Product Information 08 2007 A5E01208363 01 ...

Page 2: ...ntation Commissioning and operation of a device system may only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Prescribed Usage Note the following WARNING This device m...

Page 3: ...2 Compatibilities 6 2 Description 7 2 1 Routing of frames of the slave initiative 7 2 2 Improved link behavior during commissioning 7 2 3 Which devices can be operated behind the Y Link 8 2 4 Operation of the link on an S5 H System 8 3 Technical specifications 9 3 1 Technical specifications of the IM 153 2 6ES7153 2BAx2 0XB0 9 ...

Page 4: ...Table of contents IM 153 2 Interface Module 4 Product Information 08 2007 A5E01208363 01 ...

Page 5: ...53 2BAx1 0XB0 the interface modules indicated above contain the following new features Routing of frames of the slave initiative The link behavior for commissioning has been improved Additional documentation You will find the following supplementary documentation online at http support automation siemens com WW view en with the corresponding entry ID Name of manual Description Operating Instructio...

Page 6: ...ormation 08 2007 A5E01208363 01 1 2 Compatibilities Compatibility with predecessor versions With regard to properties and features the IM 153 2BAx2 interface module is fully compatible with its predecessor versions In addition the new features indicated above are available ...

Page 7: ...nk behavior during commissioning Starting situation The IM 153 2BAx2 interface modules are installed in one link and should be operated redundantly in an H System e g SIMATIC S7 400H Behavior of IM 153 2BAx2 If the IM 153 2BAx2 detects a redundancy partner that is not ready to be switched to or if there are no lower level slaves the interface module stops sending continuous diagnostic messages Thi...

Page 8: ... 5 The GSD must contain the following entries Prm_Block_Structure_supp 1 PrmCmd_supp 1 Slave_Redundancy_supp 1 STEP 7 checks these entries during configuration If these entries are not found the slave is then operated in DPV0 mode 2 4 Operation of the link on an S5 H System The following details are added to Chapter 11 1 2 of the Bus Links DP PA Coupler DP PA Link and Y Link Operating Instructions...

Page 9: ... of configuration frame Max 244 bytes Length of diagnostic frame Max 231 bytes Length of parameter assignment frame Max 223 bytes suitable for system modifications during operation Yes Voltages currents potentials Rated supply voltage 24 VDC 20 4 V to 28 8 V Polarity reversal protection Yes Power failure bypass 20 ms Electrical isolation to a high level DP master system Yes to the DP PA or Y coupl...

Page 10: ...p error Red LED SF Bus error on higher level DP master system Red LED BF 1 Bus error on underlying bus system Red LED BF 2 IM has an active channel Yellow LED ACT Monitoring 24 V power supply Green ON LED Data for connecting underlying bus components DP PA coupler can be connected Max 5 Y coupler can be connected 1 Underlying slaves can be connected Max 64 Number of slots in underlying slaves 244 ...