7-25
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
This test is only necessary when an encoder is used.
You can use the following flow chart to check the non-release control.
Select
Mode = jogging
Speed level 1
OVER = 100 %
Set
Speed level 1 = 0.1
@
v
max
Speed level 2 = 0.5
@
v
max
Set
Servo = ON
Is there a brief fast axis movement
with “Drive rotation direction” error message?
No
Yes
END
Read actual position
Yes
Is position control functioning?
(Axis stays in position, cannot be
pushed and does not drift away.)
Repeat “Motor actua-
tion” startup step
No
Repeat “Motor actuation /
encoder actuation” startup
step
Fig. 7-12
Non-release Control
Non-release
Control
Starting up the FM 453