7-21
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Select
Voltage level 2
Axis moving?
Start axis
Plus or minus direction
(be sure there is enough room!)
No
Yes
Is servo enable parameter-
ization correct?
Parameterization
MD37 – Servo enable
Set
Activate machine data
Check and correct drive actuation
Axis travel direction correct?
No
Yes
Parameterization
MD19 – Invert analog value
Set
Activate machine data
END
No
Yes
Select
Mode = Control
Set
Voltage level 1 = 0
Voltage level 2 = 0.1
@
U
max
Select
Set
Servo enable = ON
Start axis
Plus or minus direction
Axis idle?
Parameterization
MD44 – Adjust offset
Set
Activate machine data
Voltage level 1
No
Yes
Zeroing for
actuating signal
Traverse direction test
at 10 % of v
max
Fig. 7-8
Basic Startup of Servomotor Actuation
Starting up the FM 453