Commissioning
7.5 Notes on operation
SIMATIC Box PC 627
7-10
Operating Instructions, Release 05/2006, A5E00362052-03
Solution:
Before performing a RAID commissioning, the SIMATIC PC DiagMonitor should be
deactivated. Subsequently, it can be reactivated.
Measures:
If the DiagMonitor Management Station is in operation on your device:
•
Close all applications, also the Management Station.
•
Afterwards, stop the DiagMonitor SNMP Agent (SOL-Agent). In order to do so, select
Start > Run and enter
cmd
in the field.
•
Afterwards, enter
Net stop snmp
and confirm with the Enter key.
If your device is remotely monitored with SIMATIC PC DiagMonitor:
In this case you need only stop the DiagMonitor SNMP Agent (SOL-Agent).
•
In order to do so, select Start > Run and enter
cmd
in the field.
•
Afterwards, enter
Net stop snmp
and confirm with the Enter key.
Notice
Should the above procedure not be adhered to, a successful RAID configuration cannot
be guaranteed.