12 Monitored lines
FDOOT221
Used as combination detector
2 selectable parameter sets
Combination detector
FDOOT241
Used as combination, smoke or heat detector
5 selectable parameter sets
FDF241-9
For indoors and outdoors with
3 infrared sensors and sun resistance
Flame detector
FDF221-9
1 infrared sensor for use without interference
sources
Linear smoke detector
FDL241-9
6 parameter sets
Manual detector
FDM223
Push-button detector, actuated by pressing the
button.
Alarm sounder
FDS221
11 tones and 3 volume levels, shrill alarm sound
Signal base
FDSB291
11 configurable tones and 2 volume levels
Input module
FDCI222
4 contact inputs, monitored for wire breakage and
short circuit
4 contact inputs, monitored for wire breakage and
short circuit
Input/output module
FDCIO222
4 x 30VDC 4A relay outputs
FDnet transponder
FDCIO223
2 VdS alarm or monitored control lines
Line disconnector
FDCL221
For connecting several spur lines lying next to one
another to one ring line
Table 31: Supported Sinteso
™
elements
Nothing needs to be mechanically adjusted on the detectors themselves. The detectors are
supplied ex works with the appropriate sets of parameters. The PLAN D100 configuration tool
can be used to adjust the detectors optimally to the conditions of the installation site. By se-
lecting the right parameters you can set the detector to specific potential fire events and likely
environmental influences.
For the FDOOT241-9 neural fire detector you can also select the parameter sets of the
FDO241 wide spectrum smoke detector and the FDT241 heat detector. In this case the
FDOOT241-9 neural fire detector will behave like the FDO241 wide spectrum smoke detector
or FDT241 heat detector.
For S-LINE detectors the switching of the parameter sets can be controlled on a
time/process-related basis.
Two parameter sets within DOOT or DO or DT can be switched using an operating input on
the control and indicating panel, an operation on the operating panel of the control unit, or us-
ing the time controls on the control and indicating panel. Both parameter sets are fixed in both
PLAN D100 and in SIGMASYS detectors.
Two customized detector parameter sets can be selected for S-LINE detectors with PLAN
D100 and downloaded to the detectors via the line tester.
Installation conditions for Sinteso™ detectors and their associated parameters can be found
in the detectors' technical description.
12.6.3 Parameter sets for FDOOT, FDO and FDT detectors
Parameter sets
FDOOT241
FDOOT221
FDO241
FDO221
FDT241
FDT221
DOOT: high
X
DOOT: robust
X
X
Standard
DOOT: balanced
X
X Standard plus
DOOT: suppression
X
DOOT: fast response
X
DOOT: high compensation
X
Multifunctional Danger Control and Indicating Panels SIGMASYS C and M (M-Modules)
87 / 128
Best.Nr. A24205-A337-B970 – Edition 12 (03/07)
Summary of Contents for SIGMASYS C
Page 4: ......
Page 30: ......
Page 38: ......
Page 44: ...6 Functions 36 128 BMT Project Planning Guidelines Best Nr A24205 A337 B970 Edition 12 03 07 ...
Page 48: ......
Page 62: ......
Page 84: ......
Page 110: ......
Page 128: ...16 Appendix 120 128 BMT Project Planning Guidelines Best Nr A24205 A337 B970 Edition 12 03 07 ...
Page 130: ......
Page 132: ......
Page 134: ......
Page 137: ......