Installation and mounting
5.6 Connecting the charging station
SICHARGE D
Operating Instructions, 02/2021, 8EM5907-0AA00-1AA7.01
65
5.6
Connecting the charging station
5.6.1
Safety instructions
The installer is responsible for the electrical connection of the charging station. The electrical
connection of the charging station must be performed in accordance with the relevant
regulations (such as conductor cross-section, fuses, ground connection).
During all work on the charging station, observe the basic safety instructions (Page 8), the
requirements of DIN EN 50110-1 for safe working with and on electrical installations or
equivalent applicable local guidelines. Also observe the following safety instructions.
WARNING
Electric shock due to lack of grounding
If the protective conductor connection is missing or incorrectly connected, high voltages
may be present on exposed parts. Touching the parts can lead to serious injury or death. To
ground the charging station, connect the protective conductor properly.
WARNING
Qualified personnel
Only qualified and trained persons may work on SICHARGE D. Only qualified and instructed
electricians may work on the SICHARGE D.
WARNING
Fall arrester
Use approved protective equipment to protect persons, components and tools against
falling from a working height of 1 m.
WARNING
Falling parts
When working at an elevated height, watch out for falling parts, cables or plugs.
CAUTION
Danger to life and damage to property due to loose power connections
Insufficient tightening torques and vibrations lead to loose power connections. Loose power
connections can result in high voltages on exposed parts. Touching the parts can lead to
serious injury or death. Loose power connections can also cause fire damage, defects to the
device or malfunctions.
•
Tighten all power connections to the specified tightening torque.
•
Check all power connections at regular intervals, especially after transport.
•