Operation and Display
4.3 Key Definition
SICAM P38 P39, 3-phase Power Meter with Multi-Tariff function, User Manual
E50417-H8940-C564-
4
, Release Date
06.2018
31
Example 10:
This screen shows A display area (current voltage eligibility
rate) and B display area (current phase A current maximum
demand).
At cyclic display mode, press "
▲
" or "
▼
" to enter key display
mode. When area A is selected, press "
▲
" or "
▼
" to enter
voltage eligibility rate option.
In the figure of A, L1=99.2%, L2=100.0%, L3=98.5% and
mean voltage eligibility rate=99.2%. Press "
" to switch to
area B. Press "
▲
" or "
▼
" to switch to current phase A current
maximum demand display. Press "
" to enter second level
display. Press "
▲
" or "
▼
" to view current phase A current
maximum demand on previous 3 settlement days. Press "
"
again to enter third level display. Press "
▲
" or "
▼
" to view
maximum demand at each tariff. Press "
" to return to pre-
vious display.
Example 11:
This screen shows A display area (voltage distortion rate) and
B display area (frequency).
At cyclic display mode, press "
▲
" or "
▼
" to enter key display
mode. When area A is selected, press "
▲
" or "
▼
" again to
switch to voltage distortion rate option.
In the figure of A, L1=0.72%, L2=0.90%, L3=1.05% and
average voltage distortion rate=0.89%. Press "
" to return
to area B and press "
▲
" or "
▼
" to switch to frequency option.
Example 12:
This screen shows A display area (fundamental voltage) and
B display area (current date).
At cyclic display mode, press "
▲
" or "
▼
" to enter key display
mode. When area A is selected, press "
▲
" or "
▼
" to switch to
fundamental voltage option.
In the figure of A, L1=10.20 V, L2=11.03 V, L3=9.88 V and
mean fundamental voltage=10.37 V. Press "
" to enter
second level display. You can press "
▲
" or "
▼
" to view 2
nd
to
50
th
harmonic voltage. Press "
" to return to previous dis-
play. Press "
" again to return to area B and press "
▲
" or
"
▼
" to switch to current time display.
Example 13:
This screen shows A display area (2
nd
harmonic current ratio)
and B display area (current time).
At cyclic display mode, press "
▲
" or "
▼
" to enter key display
mode. When area A is selected, press "
▲
" or "
▼
" to switch to
2
nd
harmonic current ratio option.
In the figure of A, L1=10.02%, L2=9.11%, L3=9.73% and
mean 2
nd
harmonic current ratio=9.62%. Press "
" to enter
second level display. You can press "
▲
" or "
▼
" to view 3rd to
50th harmonic voltage. Press "
" to return to previous dis-
play. Press "
" again to return to area B and press "
▲
" or
"
▼
" to switch to current time display.