SICAM FCM Current-Transformer Adapter, Accessory
E50417-X8950-C590-A2, Edition 06.2018

              Page  2

SICAM FCM Current-Transformer Adaptor
Manual

s

Figure 1-2 Components of the Current-Transformer Adaptor SICAM FCM

Technical Data

                                                                                                                                                                                                                                   g

1-1   General Characteristics

         1-2   Environment

Characteristics

Specifications

Characteristics

Specifications

Rated input current

1 A or 5 A

Operating temperature range

-40 °C to + 70 °C

Accuracy

1 A: ± 1 %
5 A: ± 3 %

Storage temperature range

-40 °C to + 85 °C

Accuracy range

1 A: 0.4 A to 8 A
5 A: 0.4 A to 50 A

Humidity range

0 to 95 %, non-condensing

Frequency

50 Hz/60 Hz

Altitude above sea level

Maximum up to 2000 m

Thermal overload

100 A for 1 s

Rated output

225 mV

Consumption per phase
and ground path

≤ 0.1 VA (at

Ι

N

 = 1 A)

≤ 0.5 VA (at

Ι

N

 = 5 A)

1-3   Safety

         1-4   Dimensions

Characteristics

Specifications

Characteristics

Specifications

Dielectric as per IEC 61010-1  2.5 kV

Dimensions

43 mm x 90 mm x 30 mm

Impulse as per IEC 61010-1

4 kV

Weight

66 g

Vibration as per IEC 60068-2-
6/IEC 60255-21-1

Class II

Inner diameter of CT

5.8 mm

Summary of Contents for SICAM FCM

Page 1: ...e 3 current inputs 3 voltage inputs 1 digital input 2 digital outputs 1 RS485 interface Modbus RTU 1 auxiliary power supply connection on the rear side of SICAM FCM 3 Carry out all the necessary electrical connections of the cable assembly as per the following color coding of the wires Colour Coding Description Brown Connect cores to terminal 13 I1 14 I1N of SICAM FCM Blue Connect cores to termina...

Page 2: ... A 1 5 A 3 Storage temperature range 40 C to 85 C Accuracy range 1 A 0 4 A to 8 A 5 A 0 4 A to 50 A Humidity range 0 to 95 non condensing Frequency 50 Hz 60 Hz Altitude above sea level Maximum up to 2000 m Thermal overload 100 A for 1 s Rated output 225 mV Consumption per phase and ground path 0 1 VA at ΙN 1 A 0 5 VA at ΙN 5 A 1 3 Safety 1 4 Dimensions Characteristics Specifications Characteristic...

Page 3: ...lausgänge 1 RS485 Schnittstelle Modbus RTU 1 Hilfsspannungsversorgungsverbindung auf der Rückseite des SICAM FCMs her 3 Stellen Sie alle erforderlichen Verbindungen des Kabelsatzes gemäß folgender Farbcodierung der Leiter her Farbcodierung Beschreibung Braun Adern an Klemme 13 I1 14 I1N am SICAM FCM anschließen Blau Adern an Klemme 15 I2 16 I2N am SICAM FCM anschließen Orange Adern an Klemme 17 I3...

Page 4: ...ereich 40 C bis 85 C Genauigkeitsbereich 1 A 0 4 A bis 8 A 5 A 0 4 A bis 50 A Feuchtebereich 0 bis 95 nicht kondensierend Frequenz 50 Hz 60 Hz Höhe über dem Meeresspiegel Maximal bis 2000 m Thermische Überlast 100 A für 1 s Nennlast 225 mV Verbrauch pro Leiter und Erdungspfad 0 1 VA bei ΙN 1 A 0 5 VA bei ΙN 5 A 1 3 Sicherheit 1 4 Maße Merkmale Spezifikationen Merkmale Spezifikationen Dielektrikum ...

Reviews: