Outputs
46
Siemens Building Technologies
Fire Safety & Security Products
07.2009
8.2.10 Set/Unset LED on Keypad
Set/Unset LED
This output reflects the status of the partition. This means that the output is active on unset, pulsating on part
set and inactive On full set:.
8.2.11 Full Set Confirmation
Set Confirmation
This output is activated for 3 seconds on successful set (positive confirmation). If the set is unsuccessful, the
output is activated as a pulsating output for 10 seconds (negative confirmation). If delayed entries are used,
the positive confirmation does not occur until the delay time has elapsed.
NOTE
If the control panel is set using the keypad (and there is a "cannot set situation"), there will be no
output activation, but the message “Arming Impossible” will be displayed on the keypad.
8.2.12 Set/Unset
Recorder
Set Record / Control
(System Set)
This output is not activated until all active partitions are set (which have at least one assigned burglar alarm
line).
8.2.13 Alarm
for
Recorder
Alarm Record / Control
(Burglar Alarm System)
This output is activated if a burglar alarm is triggered in one of the existing partitions.
8.2.14 In Full Set
Full Set Output
(Armed at Full Set)
This output is activated if the corresponding partition is set to full set. If delayed inputs are used, activation
does not take place until the delay time has elapsed.
It is reset when the partition is switched to unset.
This Output can be used to reset detectors with available alarm memory.
8.2.15 In Part Set
Part Set Output
(Armed at Part Set)
This output is activated if the corresponding partition is set to part set. If delayed inputs are used, activation
does not take place until the delay time has elapsed.
It is reset when the partition is switched to unset
8.2.16 Bypass forced Set
Bypass / Soak
(Line Bypassed or on
Soak Test)
This output is activated if one or more inputs were bypassed through the user menu, an input was automati-
cally bypassed by a forced set or an input set to soak test in the engineer menu.
It will be resetted if the inputs are again switched on.
8.2.17 Alarm in Memory
Alarm in Memory
This output is activated if the alarm memory is set (reflects alarm LED on remote keypad).
It is reset when the alarm memory is deleted.
8.2.18 Technical Alarm
Technical Alarm
This output is activated immediately if a technical input is triggered.
It is reset when the technical input is again in the normal state.